EP1022-U1
10.2. Removing the tapping shaft assembly
1. Cut all the insulated ties bundling each sensor and lead wires with the aid of a nipper, and remove the lead wires bundled to
the wire saddles (medium, large).
2. Remove all the connectors to the main circuit board.
3. Remove the massage belt, tapping belt and intensity adjustment belt.
4. Remove the motor fitting set screws A to D, and remove the motor.
5. Remove the shield panel (fitted to the circuit) set screw E to H, and remove the shield panel and eccentric shaft spring.
6. Remove the guide plate for motor set screws I to K and remove the guide plate for motor.
7. Remove the guide plate for gear box set screws L to O.
8. Remove the Pro tektite cover for eccentric link set screws P and Q with a spanner, and remove the Pro tektite cover for
eccentric link.
9. In this state, the tapping shaft assembly and guide plate for motor, gear box can be removed
10. Remove the guide plate for gear box.
11. Remove the guide plate for motor set screws and remove the guide plate for motor.
*Caution for assembling the pro tektite cover for eccentric spring.
<Assembly procedure>
a. The tapping shaft assembly should be mounted on massage mechanism, and put the grease(WEP001Y8957) on the
spring setting hole of pro tektite cover for eccentric spring and set the one end of spring to hole as shown Figure.
b. Put the grease(WEP001Y8957) on the spring setting hole of Shield panel for PCB and set the other end of spring to hole
of Shield panel for PCB.
c. Mount the Shield panel for PCB on massage mechanism.