DSC HS2016 Reference Manual page 39

Powerseries neo control panels
Hide thumbs Also See for HS2016:
Table of Contents

Advertisement

Section 4: System Operation
[12] Global Stay Arm
This function arms all partitions assigned to the user in Stay mode, provided they are ready to arm. If a partition is not ready,
the system cannot be armed. An access code is required with this option.
[13] Global Away Arm
This function arms all partitions assigned to the user in Away mode, provided they are ready to arm. If a partition is not ready,
the system cannot be armed. An access code is required with this option.
[14] Global Disarming
This function disarms all partitions assigned to the user. An access code is required with this option.
[16] Quick Exit
Pushing this key allows the user to open and close an entry/exit door without disarming the system. This function is equi-
valent to entering [*][0] at the keypad while the partition is armed. If quick exit is not enabled on the system, or if the system is
disarmed, pressing this key causes an error tone. An access code is not required to use this key. See "[015] System Option
3" on page 88 for more information.
[17] Arm Interior
This key removes or enables automatic bypass on all Stay/Away zones (equivalent to pressing [*][1] while armed).
If this function is performed while stay armed and, Night zones are programmed, the system arms in Night mode. If no Night
zones are programmed, the system arms in Away mode. If armed in Night or Away mode, this key switches the system back
to Stay mode. Pressing this key does not switch the arming mode from Night to Away.
This key only works while the system is armed and requires an access code entry if section [015] option 4 is disabled.
[21]-[24] Command Output 1 to 4
This function controls command outputs 1-4 and is the equivalent of entering [*][7][X], where X is 1, 3 or 4.
An access code is required to use this function.
Selecting command output 2 is the equivalent of pressing [*][7][2] sensor reset. See "103 – Sensor Reset [*][7][2]" on page 73
for more information.
[29] Bypass Group Recall
This function bypasses all zones belonging to the bypass group.
Zones must be saved in the bypass group for this function key to operate. An access code is required to use this feature if
section [023] option 4 is enabled.
Note: Do not use with wireless keys.
[31] Local PGM Activate
This function controls a PGM connected to a keypad.
[32] Bypass Mode
This function places the keypad in Zone Bypass mode. Selecting this function is the equivalent of pressing [*][1] while dis-
armed. If an access code is required for bypassing, the user must enter the access code before using this function. An
access code is required if section [023] option 4 is enabled.
[33] Bypass Recall
This function bypasses the same set of zones that were bypassed the last time the partition was armed. This function is equi-
valent to pressing [999] while in the [*][1] menu. An access code is required to use this feature if section [023] option 4 is
enabled.
[34] User Programming
This function is the equivalent of entering [*][5]. A master or supervisor access code is required to use this function. This key
only works while the system is disarmed.
[35] User Functions
This function puts the keypad in user programming mode and is the equivalent of entering [*][6]. An access code is required
to use this function. If section [023] option 8 is off, only the Master or Supervisor code can access the [*][6] menu.
[37] Time & Date Program
This function places the keypad in date/time programming mode. A valid access code is required.