MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
85
VCC2
-
86
EXT AMP CON
I/O
86
NC
O
87
VSS
-
88~91
TYPE 1~TYPE4
I
92
NC
-
93
OEM DISP DATA
I/O
93
NC
O
94
OEM DISP CLK
I/O
94
NC
O
95
OEM DISP CE
I/O
95
NC
O
96
NC
-
97
P CON
O
98
NC
-
99
ANT CONT
O
100
ILLUMI DET
I
101
BU DET
I
102
ACC DET
I
103
(PWIC SVR)
O
104
PWIC MUTE
O
105
PWIC STBY
O
106
LX CON
O
107
MUTE PRE R
O
107
NC
O
108
CD MUTE PRE L
O
108
MUTE_PRE
O
109
MUTE 0
O
110
MUTE 1
O
111
MUTE 2
O
112
NC
O
113
DSP MUTE
I/O
113
NC
O
114
MUTE C
O
114
NC
O
115
DSP INIT RST
O
115
NC
O
116
DSP S RST
O
116
NC
O
Function
External amplifier control
Not used
Destination switching
Not used
External display DATA
Not used with DISP OUT
External display CLK
Not used with DISP OUT
External display control request
Not used with DISP OUT
Not used.
External amplifier control
Not used.
Power antenna control
Dimmer illumination detection
Momentary power down detection
ACC power supply detection
SVR discharge circuit
Power IC mute
Power IC standby control
Start up request to slave unit
Rch pre-out mute
Not used when MD
Lch pre-out mute
PRE_OUT MUTE (MD)
E-VOL front mute
E-VOL rear mute
E-VOL sub mute
Not used
DSP mute
Not used when without DSP
E-VOL AFS mute
Not used (in other than when the destination is E)
DSP initial reset
Not used when without DSP
DSP system reset
Not used when without DSP
KDC-W8534/W8534Y
KDC-X790
Processing Operation
Fixed to L-output for models without EXT_AMP
Refer to Truth Value Table y
External display
Output L fixed
External display
Output L fixed
External display
Output L fixed
POWER ON : H, POWER OFF or STANDBY : L
TUNER ON : H
L : ON, H : OFF
BU : L, No BU or momentary power down : H
ACC ON : L, ACC OFF : H
H : 5 seconds after POWER OFF and momentary
power down, Then : L
L : When STANDBY source or momentary power
down, L : When TEL MUTE
POWER ON : H, POWER OFF : L
H : SLAVE UNIT ON, L : SLAVE UNIT OFF
L : When "MUTE PRE R" is "L" or at momentary
power down, H : Only when 2-zone
Output L fixed
L : When "MUTE PRE L" is "L" or at momentary power
down, H : Only when 2-zone
L : When at momentary power down
ON : L, OFF : H
ON : L, OFF : H
ON : L, OFF : H
ON : L, OFF : Hi-Z
Output L fixed
ON : L, OFF : H
Output L fixed
L : Reset, H : Reset release
Output L fixed
L : Reset, H : Reset release
Output L fixed