2-5. REMOVAL OF
MODULE HOUSING
2-2
If the need for extensive service is required on the module compo-
nents, the entire outer shell of the module can be removed to make
servicing easier. To remove the outer shell of the module, follow
these procedures:
1. Remove the module from the cabinet per Module Removal
Section.
2. Remove the six (6) screws that are located on the sides of the
module.
Step 2
3. Remove the four (4) screws located at the corners of the
module top.
4. Remove the screws from the control panel and the back
panel, that fasten them to the module housing.
5. Lift the shell of the module off the unit.
Step 3
6. When work is completed, reassemble in reverse order.
Step 4
Step 5