4-4. Overall Electrical Alignment
6. Repeat the steps 4 and 5 alternately, until the beam
spot is minimized on the vectorscope.
(Vector scope)
7. Confirm that the carrier leakage does not monitored at
portion C on the waveform monitor.
Specifications: C = Minimum
(Waveform Monitor)
8. Set the menu as follows.
MENU : Paint
PAGE
: Video Level (P1)
ITEM
: Test→Off
9. WHITE BAL switch (on the side panel) → PRST
4-40(E)
4-4-17. Flare Adjustment
Equipment : Waveform monitor
Test point : TEST OUT connector
Object
: Grayscale chart
Preparations:
Connect the waveform monitor to the TEST OUT connec-
tor.
Shoot the grayscale chart so that the chart frame is aligned
with the underscanned monitor frame.
(Waveform Monitor)
Set the menu as follows.
MENU : Paint
PAGE
: Knee/W.Clip (P6)
ITEM
: Knee→OFF
RGB/ENC switch (on the side panel) → ENC
Adjust the iris control of the lens to satisfy the white level
A.
A = 100 ±2 IRE (for NTSC)
A = 700 ±14 mV (for PAL)
(Waveform Monitor)
BVP-550
BVP-550P