1-1. Connectors and Cables
1-1-1. Connector Input/Output Signals
Output Signal
• TEST OUT
BNC 75 Ω 1.0 Vp-p
REMOTE (6P FEMALE)
(EXTERNAL VIEW)
No. SIGNAL
1
SERIAL DATA IN
2
SERIAL DATA OUT
3
UNREG (G)
4
VBS (X) OUT
5
VBS (G) OUT
6
UNREG OUT
BVP-550
Section 1
Installation
SPECIFICATIONS
Serial data for camera control
VBS 1 Vp-p, Zo = 75 Ω
+10.5 V to +17 V
MIC IN (3P FEMALE)
)
(EXTERNAL VIEW)
No.
SIGNAL
1
MIC IN (G)
2
MIC IN (X)
3
MIC IN (Y)
SPECIFICATIONS
–60 dBu High impedance
balanced
(0 dBu=0.775 Vrms)
1-1 (E)