4.1.3
Slot [1-1] LCO Card Property
The properties of the analog CO line cards can be specified.
Outgoing Guard Time
Specifies the length of time after a CO line is disconnected, during which the PBX cannot seize
the line.
Default
Value Range
Feature Guide References
Feature References
•
Programming References
•
First Dial Timer (CO)
Specifies the minimum time that the PBX waits after seizing a CO line, before sending the
dialed digits to the telephone company. This allows the telephone company to have enough
time to accept the dialed digits correctly.
Default
Value Range
Feature Guide References
Feature References
•
Programming References
•
CO Feed Back Tone
Specifies whether to turn on or turn off the pulse feedback tone. For outgoing CO line calls, the
dialed number is toned out, which informs the extension user that the dialed number has been
dialed out.
Default
Value Range
None
4.1.1 Slot [1-1]
3 s
3–6 s
None
4.1.1 Slot [1-1]
1.0 s
0.5 × n (n=1–16) s
None
4.1.1 Slot [1-1]
Yes
No, Yes
4.1 Configuration [1]
Feature Guide