30
No.
Description
1
Input busbars.
2
Main switch-disconnector (option +F253) in a dedicated cubicle.
3
Grounding switch (option +F259).
4
AC fuses. Only present if the drive is equipped with a main switch-disconnector or main breaker.
5
Supply modules.
+ Behind each module: quick connector.
6
Supply unit control board (mounted sideways).
7
Inverter DC fuses.
8
Inverter modules.
+ Behind each module: quick connector for the inverter module output connection.
+ Behind each module: output terminals. Motor cables connect here if a common motor terminal cubicle (option +H359) is not present.
+ Motor (output) cable lead-throughs.
9
Swing-out frame. Contains the inverter unit control board with I/O terminals, and provides space for standard and optional electrical equipment.
+ Accessible by opening the swing-out frame: auxiliary voltage transformer.
10
Auxiliary voltage switch-disconnector.
11
APBU board for communication between the DSU control board and the parallel-connected DSU modules.
12
APBU board for communication between the inverter unit control board and the parallel-connected inverter modules.
13
CVAR boards.
14
BAMU board.