Navien NR-180 Installation Manual page 44

Hide thumbs Also See for NR-180:
Table of Contents

Advertisement

Gas Water Heater Installation
5. Cascade system Plumbing Pipe Size (@ NR/NP-240(A))
△T=86 ºF
Q'ty
Flowrate
(GPM)
1
7.19
2
14.38
3
21.57
4
28.77
5
35.96
6
43.15
7
50.34
8
57.5
9
64.72
10
71.92
11
79.11
12
86.30
13
93.49
14
100.68
15
107.87
If the flow rate inside pipes is over 6.6 ft/s, corrosion might be occurred
inside the pipes.
Above state may be different depending on installation circumstance.
44
Velocity
Pipe
of Water
Diameter
Q'ty
(ft/s)
(mm/in)
3/4"
4.78
20A
16
1"
5.61
25A
17
11/4"
5.54
30A
18
5.21
40A
11/2"
19
11/2"
6.53
40A
20
2"
4.49
50A
21
2"
5.24
50A
22
2"
6.00
50A
23
21/2"
4.39
65A
24
21/2"
4.75
65A
25
21/2"
5.34
65A
26
21/2"
5.84
65A
27
21/2"
6.33
65A
28
21/2"
6.79
65A
29
3"
5.11
80A
30
△T=86 ºF
Velocity
Pipe
Flowrate
of Water
Diameter
(GPM)
(ft/s)
(mm/in)
115.07
5.44
80A
122.26
5.81
80A
129.45
6.14
80A
136.64
6.46
80A
143.83
6.83
80A
151.02
4.06
100A
158.21
4.25
100A
165.41
4.45
100A
172.60
4.65
100A
179.79
4.85
100A
186.98
5.05
100A
194.17
5.24
100A
201.36
5.44
100A
208.56
5.61
100A
215.75
5.81
100A
3"
3"
3"
3"
3"
4"
4"
4"
4"
4"
4"
4"
4"
4"
4"