Model Number Nomenclature - Carrier 48HC*04–14 Service And Maintenance Instructions

Nominal 3 to 12.5 tons with puron (r410a) refrigerant
Table of Contents

Advertisement

APPENDIX I. MODEL NUMBER NOMENCLATURE
Unit Heat Type
48
Gas Heat
Packaged
Rooftop
Series/Model
HC
Standard Efficiency
Heat Size
D -
Low Heat
E -
Medium Heat
F -
High Heat
L -
Low NOx, Low Heat
M -
Low NOx, Medium Heat
N -
Low NOx, High Heat
S -
Stainless Steel, Low Heat
R -
Stainless Steel, Medium Heat
T -
Stainless Steel, High Heat
(Low NOx models include - Stainless Steel HX
Refrigeration Systems Options
A -
Standard One-Stage Cooling Models
B -
Standard One-Stage Cooling Models
with Humidi-MiZer (04 - 07 Models only)
D -
Two-Stage Cooling Models, 08-16
E -
Two-Stage Cooling Models, 08-16
with Al/Cu Condenser Coils and
Humidi-MiZer
Cooling Tons
04 - 3 Ton
08 - 7.5 Ton
05 - 4 Ton
09 - 8.5 Ton
06 - 5 Ton
12 - 12.5 Ton
07 - 6 Ton
14 - 12.5 Ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
Sensor
2
F =
RA Smoke Detector and CO
Sensor
2
G = SA Smoke Detector and CO
Sensor
2
H = RA + SA Smoke Detector and CO
Indoor Fan Options 3,4, 5 Ton Models Only*
0 =
Electric (Direct) Drive X13 Motor
2 =
Medium Static Option - Belt drive
3 =
High Static Option - Belt Drive
Indoor Fan Options 6 - 12.5 Ton Models Only*
1 =
Standard Static Option - Belt Drive
2 =
Medium Static Option - Belt Drive
3 =
High Static Option - Belt Drive
C =
High Static option w/High Efficiency Motor - Belt
Drive (Size 14 only)
*See price page details for specific Humidi-MiZer models.
Note: On single phase (-1 voltage code) models,
the following are NOT available as a factory
installed option (FIOP):
-
Humidi-MiZer
-
Coated Coils or Cu Fin Coils
-
Louvered Hail Guards
-
Economizer or 2 Position Damper
-
Powered 115 VAC Convenience Outlet
H
Sensor
2
Coil Options for Round Tube/Plate Fin Condenser Coil Models
Only (outdoor-indoor-hailguard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-Coat Al/Cu - Al/Cu
D = E-Coat Al/Cu - E-Coat Al/Cu
E = Cu/Cu - Al/Cu
F =
M = Al/Cu -Al/Cu - Louvered Hail Guards
N = Precoat Al/Cu - Al/Cu - Louvered Hail Guards
P = E-Coat Al/Cu - Al/Cu - Louvered Hail Guards
Q = E-Coat Al/Cu - E-Coat Al/Cu - Louvered Hail Guards
R = Cu/Cu - Al/Cu - Louvered Hail Guards
S = Cu/Cu - Cu/Cu - Louvered Hail Guards
Coil Options for All Aluminum - Novation Condenser Coil Models
Only (outdoor-indoor-hailguard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J =
K = E-Coat Al/Al - Al/Cu - Al/Cu
L =
T =
U = Al/Al - Cu/Cu - Louvered Hail Guards
V = Al/Al - E-Coat Al/Cu - Louvered Hail Guards
W= E-Coat Al/Al - Al/Cu - Louvered Hail Guards
X = E-Coat Al/Al - E-Coat Al/Cu - Louvered Hail Guards
Fig. 75 - - Model Number Nomenclature
Packaging and Seismic Compliant
0 =
Standard
1 =
LTL
3 =
CA Seismic Compliant
4=
LTL and CA Seismic Compliant Label
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-the-Base Connections
F =
Non-Fused Disconnect and Thru-the-Base Connections
G = 2-Speed Indoor Fan (VFD) Controller
J =
2-Speed Fan Controller (VFD) and Non-Fused Disconnect
K = 2-Speed Fan Controller (VFD) and Thru-the-Base Connections
M = 2-Speed Fan Controller (VFD) with Non-Fused Disconnect and
Thru-the-Base Connections
Service Options
0 =
None
1 =
Unpowered Convenience Outlet
2 =
Powered Convenience Outlet
3 =
Hinged Panels
4 =
Hinged Panels, Unpowered Convenience Outlet
5 =
Hinged Panels, Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F =
Enthalpy Economizer w/ Barometric Relief
K = 2 - Position Damper
U = Temp Ultra Low Leak Economizer with Barometric Relief
W = Enthalpy Ultra Low Leak Economizer with Barometric Relief
Base Unit Controls
0 =
Base Electromechanical Controls
1 =
PremierLink Controller
2 =
RTU-Open Multi-Protocol Controller
6 =
Electromechanical w/ 2-Speed Fan and W7220 Econo Controller
Design Revision
- = Factory Assigned
Voltage
1 =
575/3/60
5 = 208-230/3/60
3 =
208-230/1/60
6 = 460/3/60
Cu/Cu - Cu/Cu
Al/Al - E-Coat Al/Cu
E-Coat Al/Al - E-Coat Al/Cu
Al/Al - Al/Cu - Louvered Hail Guards
65
C12096