Connecting The Cable - Samsung AC024JXADCH Installation Manual

Hide thumbs Also See for AC024JXADCH:
Table of Contents

Advertisement

Connecting the cable

Two electronic cables must be connected to the outdoor unit.
The connection cord between indoor unit and outdoor unit.
The power cable between outdoor unit and auxiliary circuit breaker.
Be sure to run the power supply cable and the communication cable through
electrical conduit as seen in the picture.
Separately protect the power and communication cable using approved conduit.
- Conduit is not supplied with the product.
Make a knockout hole.
After making a knockout hole, apply rust resisting paint around the hole.
Secure the cable tube to the outdoor knockout using the CD connector and
bushing.
• During unit installation make refrigerant connections first then
electrical connections. If removing the unit disconnect electrical
CAUTION
cables first, then refrigerant connections.
• Connect the air conditioner to grounding system before
performing the electrical connection.
• When installing the unit, you shouldn't use inter connection
wire.
Example of Air Conditioner System
When using ELCB for 1 phase
OR
❋ If an outdoor unit is installed in a place in danger of an electric leak or submergence, you must install the ELCB.
• AC030JXSCCH, AC036JXSCCH
- ELCB must be installed since this product is equipped with a base heater.
CAUTION
Communication cable
Outdoor Unit
Grounding
Power cable
Conduit
Power cable
Communication cable
Indoor Unit
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents