Unsatisfactory Cooking - Samsung M1714R Service Manual

Hide thumbs Also See for M1714R:
Table of Contents

Advertisement

6-2 Unsatisfactory Cooking

Parts
-
Food is
not heated.
6-3 Part Check List
Symptom
Microwave
cooking does
not work.
Fan motor
does not rotate.
Samsung Electronics
Downloaded from
www.Manualslib.com
Cause
1) Open cathode
Check the terminals with a multimeter to see
of magnetron
if the heater circuit is open.
2) Defective
Check the H. V. Diode for continuity in the reverse and
H. V. Diode
normal directions using megger. If there is continuity
in the reverse direction, the H. V. Diode may be faulty.
(In this event H. V. Capacitor will be hot)
3) Shorted
Connect megger leads to quick-connect terminal &
magnetron
body of the magnetron if there is continuity, the
magnetron may be faulty. (In this case the main
fuse will be blown)
4) Defective
If there is a crack in the magnetron antenna (dome),
magnetron
the magnetron is defective.
5) Poor contact
Check if the screws are secured well to the door hinge.
of primay
and pressing it ON and OFF repeatedly.
interlock switch
6) Open coil of
Check the continuity of primary coil and secondary
H. V. Trans-
coil. If there is no continuity, H. V. Transformer is
former
defective.
7) Shorted H. V.
Check the continuity of capacitor.
capacitor
If the capacitor shorts, the fuse blows
8) Monitor fuse
Check the monitor fuse
blown out
(on the noise filter)
Related Parts
H.V.Transformer
1) Check if the primary and secondary coil is open or shorted.
2) Check if the MGT Heater Voltage is approx. 3.3V AC.
H.V.Capacitor
Check continuity of capacitor between two
terminals with H.V.wire lead removed.
The resistance should be approx. 10MW, it's failure.
H.V.Diode
1) If there is no continuity in forward, direction the H.V.Diode is open.
2) If there is continuity in reverse direction, it's shorted.
Fan motor
Check if the motor coil is open.
manuals search engine
Diagnosis
Check Points
* Resistance of primary coil: Approx. 2.30 Ω
Resistance of secondary coil: Approx. 123 Ω
Caution : High voltage !
Troubleshooting
Remedy
Replace magnetron.
Replace H. V. Diode.
Replace magnetron.
Replace magnetron.
Replace or adjust.
Replace the
H. V. Transformer.
Replace the
H. V. Capacitor.
Replace the
Monitor fuse
Remedy
Replace.
Replace.
Replace.
Replace.
6-3

Advertisement

Table of Contents
loading