A
Battery connection scenario A: suitable for a vessel with
a common RF ground point. In this scenario, if your
product's power cable is supplied with a separate drain
wire then it should be connected to the vessel's common
ground point.
B
Battery connection scenario B: suitable for a vessel
without a common grounding point. In this case, if your
product's power cable is supplied with a separate drain
wire then it should be connected directly to the battery's
negative terminal.
Implementation — connection to distribution
panel
• Alternatively, the supplied power cable may be
connected to a suitable breaker or switch on the
vessel's distribution panel or factory-fitted power
distribution point.
• The distribution point should be fed from
the vessel's primary power source by 8AWG
(8.36mm
2
) cable.
• Ideally, all equipment should be wired to individual
suitably-rated thermal breakers or fuses, with
appropriate circuit protection. Where this is not
possible and more than 1 item of equipment
shares a breaker, use individual in-line fuses
for each power circuit to provide the necessary
protection.
• In all cases, observe the recommended
breaker / fuse ratings provided in the product's
documentation.
• If you need to extend the length of the power cable
supplied with your product, ensure you observe
the dedicated Power cable extensions advice
provided in the product's documentation.
Important: Be aware that the suitable fuse rating
for the thermal breaker or fuse is dependent on the
number of devices you are connecting.
Cables and connections (Quantum variant with RayNet)
Grounding
Ensure that you observe the separate grounding
advice provided in the product's documentation.
More information
Raymarine recommends that best practice is
observed in all vessel electrical installations, as
detailed in the following standards:
• BMEA Code of Practice for Electrical and
Electronic Installations in Boats
• NMEA 0400 Installation Standard
• ABYC E-11 AC & DC Electrical Systems on Boats
• ABYC A-31 Battery chargers and Inverters
• ABYC TE-4 Lightning Protection
Warning: Grounding not
required
This product is fully insulated and does
NOT require separate grounding.