12. TROUBLESHOOTING

12-1 INFORMATION OF LINEAR COMPRESSOR

The information tag provides compressor model, refrigerant, serial number and safety approval
Name Plate
FLB075LANA
Size : 90mm X 20mm
There are two types of controllers used in the linear compressor system.
- The "A"-inverter system is used with theFLB075L*NA compressor.
FLB075L*NA
E-Inverter
System
Refrigerator
Controls the
algorithm
according to
various
conditions.

Compressor Label

1. Compressor Model
F L B 0 7 5 L * N A
Series name
DLF/FA/FB/FLA/FLB
Displacement
ex)90=9.0cm³ /stroke
Application Category
- L : LBP with R134a
- H : HBP with R134a
- N : LBP with R600a
2. Refrigerant
3. Serial Number
00 00 9 2003 5 13 0012
Buyer Code
Model Code
Line
4. Safety Approval
Ex)
Comp Drive
Inverter
VVVF
**CVCF : Variable Voltage Variable Frequency
**CVCF : Constant Voltage Constant Frequency
Operating Type
A : A-Inverter
E : E-Inverter
Rated Voltage
& Frequency
- M : 220V 50/60Hz
- N : 115V 50/60Hz
Efficiency version
A : 1
st
generation
B : 2
nd
generation
Serial No.
Date
Month
1 : January
O : October
N : November
~
Year
9 : September D : December
Compressor
Stroke
Modulation