8-3 Icing Sensor Error (E IS)

Symptom
1. E IS
1. Check for a loose connection
2. Check Sensor Resistance
CON5
th
15
pin ~ 17
pin
CON5
th
15
pin ~ 17
pin
-22ºF /-30ºC
-13ºF /-25ºC
-4ºF / -20ºC
-13ºF /-25ºC
14ºF / -10ºC
23ºF / -5ºC
32ºF / 0ºC
Check Point
CON5
Resistance [Ω]
Short
th
Open
Other
Resistance [ ]
Ω
th
40k
30k
23k
17k
13k
10k
8k
0
OFF
Normal

Hide quick links: