4. 20 Cleaning of dedicated path for Low volatilization system (UX-E only)

• Periodical cleaning of the dedicated path for Low volatilization system shall be conducted
in order to maintain proper operation of the printer.
(It is recommended the cleaning is conducted at the time of periodical maintenance of the printer.)
1 While cleaning is conducted, the liquid will drip from the Printhead and the Exhaust duct.
Please make sure you conduct following tasks beforehand for preparation.
(a) Makeup will drip from the Printhead.
Remove the Printhead cover, and place
the tip of the Printhead into the beaker.
(b) Makeup will drip from the Exhaust duct.
Place a fluid pan or a wiping paper under the Exhaust duct.
2 Remove the Tube lock of the Exhaust tube (Piping [5] ) which is connected to the Main ink tank, and
connect the Piping [5] to Hand pump.
Exhaust tube (Piping [5])
Exhaust tube (Piping [1])
Fluid pan or wiping paper
Exhaust duct
Hand pump specifications
Part name: Nozzle cleaner
Part No: 451000
Hand pump
4-59
Beaker