[Caution] When replacing 0-C000:
1. There is CCD ID No. seal on the plate. *The No. can be readable.
2.Peel off the seal on the plate then replace the seal on the pentaprism.
*

15. [ADJUSTMENT] HEIGHT OF 0-C000

[Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as *istD series or K100D)
Specified glue: Cemedine Super-X (Clear) --- Order number 95901 A133
① Measure height of the CCD rear plate (3 places) from the mount surface as shown in the figure.
Tolerance (For 76830 only):
With using Block gauge for 35mm
(45.46mm):
② [Adjustment] Turn three adjustment screw A31. Target for adjustment is +5.83±0.00 (Maximum
and minimum difference is within 0.01)
You must finish the adjustment with turning A31 tighten direction. (Clockwise direction)
③ After adjustment, clean A31 and around A31 by solvent then apply super-X on the top of screw
as shown in figure.
ADJ
Confirm for not
disassembled body
51.22~51.37 mm
+5.76~5.91 mm
Super-X
(Clear)
36
When adjusting
51.29±0.01 mm
+5.83±0.01 mm
(+5.82~5.84 mm)
+0.83
Exampl
A31
+5.