If user pulls out cable from side of cable channel, it must go through the U-shape channel on
dome pedestal, and take out cable from the side exit hole on pedestal.
Step3
Adjust the device installation pedestal to the proper position and then pull cable through the exit hole
on Installation surface. Make direction of TOP sign same as it on installation position map. Remove
the installation template label and attach the camera with 3 screws (locally procured).
Fix dome body on installation surface.
Step 4
Hold rotating bracket on both sides with hand, horizontally rotate bracket, adjusting lens horizontal
direction to designated position. Loosen two hand screws on both sides of fixed rotating bracket.
(Loosen only, do not take it down), hold the camera module body with hand, making lens rotate
vertically. Adjust vertical direction of lens to appropriate angle, and fasten the M2 screw. Range of lens:
vertical (0°~+75°), horizontal (0°~+355°). See Figure 2-2.
Then, please adjust the viewing angle and focus.
Notes:
・Viewing angle and focus adjustments shall be performed together with camera angle adjustment.
・Refer to the operation manual (included in the CD-ROM) for how to perform the zoom and focus
settings from system menu.
Step 5
Take dome enclosure, put it back on the camera properly regarding to screw and hole, and fasten the
three inner hex screws with wrench.