WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
4. CONVERTING THE SURFACE BURNERS
Remove the conversion kit
(see illustration below).
LP orifice spuds have a orifice code on the top or
the side, denoting the location on the range
where it is to be installed.
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Conversion Kit
Top burner orifices
CONVERSION TO LP GAS
Denotes
orifice
code
Broil and Bake
burner orifices
For Model
LRG3091ST /00
LRG3091SB /00
LRG3091SW /00
1) Remove grates, burner caps and burner
heads.
2) Remove the brass orifice spud in the chimney
of each burner using a 5/16" or 8mm nut
driver.
3) Install the LP orifice spuds into their correct
positions as described previously.
BURNER OUTPUT RATINGS; BTU/HR
LP (Propane) Gas, 10" W.C.P
MODEL
BURNER
LF
LR
RR
RF
CTR
BROIL
BAKE
Denotes orifice code
Top burner orifices
Orifice Locations for LP Gas
M
M
L
5-2
Product Code
FG4124ES.FSTELGA
FG4124EB.FBKELGA
FG4124EW.FWHELGA
BTU RATE
ORIFICE CODE
LRG3091S
LRG3091S
9,500
L
9,100
M
5,000
P
Q
10,000
9,100
M
13,500
F
18,000
D
Broil and Bake
burner orifices
P
Q