Adjustment When The Service Panel Assy Is Replaced - Pioneer PDP-4271HD Service Manual

Plasma display system
Hide thumbs Also See for PDP-4271HD:
Table of Contents

Advertisement

1

7.5 ADJUSTMENT WHEN THE SERVICE PANEL ASSY IS REPLACED

When the Panel Assy is replaced with one for service, the following adjustments are required:
Adjustments of Vofs voltage and Vyprst voltage
Enter the reference adjustment values for the Vofs voltage and Vyprst voltage that are written on the label attached to the
A
panel for service.
Note: Enter the values, using an RS-232C command or the Factory Menu.
(Rear of the Panel)
Using an RS-232C command
Enter a "PFY" command with Factory mode ON.
B
Convert the adjustment voltage values written on the label attached at the rear of the Panel to an input command, referring to
the conversion chart. (See the next page.)
• Reference adjustment of the Vofs voltage: Ex. "Vofs = 35" → (Check the conversion chart.) Enter "VOF112."
• Reference adjustment of the Vyprst voltage: Ex. "Vyprst = 270 V" → (Check the conversion chart.) Enter "VRP078."
Using the Factory Menu
1
5
10
1
P
A
N E L
F A C T
.
5
C
10
P
A
N E L – 1
A D
J
15
16
Select the main item "PANEL FACT." by pressing the MUTE key then enter Panel Factory mode by pressing the SET key.
Using the 5/∞ keys, select "PANEL-1 ADJ" then press the SET key to enter the next lower nested layer.
Select "VOL-OFFSET" or "VOL RST P" then enter a command value converted from the voltage value, using the 2/3 keys.
D
Clearing data on various histories of the Panel, such as those on the hour meter
• It is necessary to clear the data on the hour meter, etc. to match them to the actual driving hours of the Panel.
• It is also necessary to clear the data on SD and PD, because the accumulated power-on time when a shutdown or power-
down occurred is recorded.
Note: Clear the values, using an RS-232C command or the Factory Menu.
There are two types of hour meters. Do not take the MTB hour meter for the hour meter.
Using an RS-232C command
To acquire the accumulated power-on time of the product itself, use the "QS2" of RS-232C command.
1. To clear the data on the hour meter (for the Panel) : CHM
2. To clear the data on the pulse meter
3. To clear the data on the SD history
E
4. To clear the data on the PD history
Using the Factory Menu
See "7.1.6 HOW TO CLEAR HISTORY DATA."
F
116
1
2
AWU∗∗∗∗
Vofs = 35V Vyprst = 270V
Hour Meter
15
20
25
30
32
V
D 1
1
1 6 0
1
– N T V
J
H
S 6
[
6 0 V S ]
T
B
L
1
/
( + )
: CPM
: CSD
: CPD
PDP-4271HD
2
3
AWU∗∗∗∗
Vofs = 35V Vyprst = 270V
Space
H
Hour Meter
1
5
10
1
P
A
N E L
F A C T
.
P
A
N E L – 1
A D
J
5
10
15
V
O
L
R S T
P
< = >
16
3
4
1520
H
Write in the value for the hour
meter when the Panel is
replaced (ex. 1520H).
15
20
25
30
32
V
D 1
1
1 6 0
1
– N T V
J
H
S 6
[
6 0 V S ]
T
B
L
1
/
: 0
5
8
4