Initial Test Equipment Control Settings; Radio-To-Radio Cloning - Motorola CP140 Basic Service Manual

Commercial series
Hide thumbs Also See for CP140:
Table of Contents

Advertisement

Radio Tuning and Programming: Radio-to-Radio Cloning
5.3.1

Initial Test Equipment Control Settings

The initial test equipment control settings are listed in
Monitor Mode: Power Monitor
RF Attenuation: -70
AM, CW, FM: FM
Oscilloscope Source: Mod
Oscilloscope Horizontal: 10 mSec/Div
Oscilloscope Vertical: 2.5 kHz/Div
Oscilloscope Trigger: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Volume: 1/4 CW
5.4

Radio-to-Radio Cloning

1. Cloning is the process of copying the content of one radio (source radio) into another radio (desti-
nation radio). Radio content refers to system-type features such as frequency, squelch type
options, trunking, etc.
Note: The source radio's serial number cannot be blank.
Radio functionality inherent in one radio cannot be cloned to another radio that does not contain the
same functionality. Tuning and alignment information are not transferable and are not affected by
cloning.
1. Signaling Identification Numbers (IDs) are duplicated in the cloning process. Unique IDs may be
assigned with the CPS.
Note: Unsuccessful cloning attempts generates a continuous tone and may be an
indication that the destination radio's codeplug is corrupted.
Table 5-1. Initial Equipment Control Settings
Service Monitor
Table
5-1.
Test Set
Power Supply
Speaker set: A
Voltage: 13.2 Vdc
Speaker/load:
DC on/standby:
Speaker
Standby
PTT: OFF
Volt Range: 20 V
Current: 20 A
5-3