Lincoln Electric FlexCut 80 Operator's Manual page 41

12249, 12589
Hide thumbs Also See for FlexCut 80:
Table of Contents

Advertisement

FLEXCUT™ 80
No pilot arc established
Trigger Locked
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized
Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
Error condition list
On
(Green LED)
1. The machine output is triggered. During this period the machine will attempt to
start the pilot arc 4 times. If the pilot arc does not start, the machine automati-
cally will enter into a safe status condition that will allow troubleshooting as
necessary.
2. To restore the machine:
• Turn OFF the Power switch.
• Check the correct placement of the Torch consumables and parts.
• Check the Torch electrical connections.
• Turn ON the machine.
V
On
(Green LED)
1. This occurs if the machine is turned ON (or if it is restarted after Thermal reset)
with the Torch Trigger pulled. This condition avoids unsafe operating condi-
tions. The machine is disabled such that manual cutting or gouging processes
can ONLY be initiated under the direct control of the operator.
2. To restore the machine:
• Release the Torch Trigger.
• The LED's will return to normal status and cutting or Gouging may resume.
3. If this error condition persists, check for a malfunctioning torch or remote
connection trigger.
E-7
V
On
(Yellow LED)
On
On
(Yellow LED)
(Yellow LED)
CAUTION
TROUBLESHOOTING
On
(Yellow LED)
On
(Yellow LED)