Lexmark S 500 SERIES Service Manual page 27

Table of Contents

Advertisement

Lexmark S500 Series
Error
Name
Code
1217
Printhead Temperature Error
1218
Serial Flash Error
1219
Undefined Signal Error
2100
Unlock Scanner
2200
Scan Carrier Stall
2-8
Service Manual
Description
There is a problem determining
temperature.
Invalid parameters have been
passed to ReadFlashPage.
Microprocessor has
encountered a bad signal
(other than an abort, illegal
instruction, or arithmetic
exception).
Scanner mechanism is locked
in place or unable to move due
to other failure.
The scan carrier has stalled.
Action
Technical Support Center:
Check and clean the contacts. If the
problem persists, then replace the
printhead.
Service:
Check and clean the contacts. If the
problem persists, then replace the
printhead.
Technical Support Center:
Unplug the All-In-One from the wall outlet;
wait a few seconds, then plug the All-In-
One back in and turn the power on. If the
problem remains, then replace the All-In-
One.
Service:
Replace the system board. See
board removal" on page
Technical Support Center:
Unplug the All-In-One from the wall outlet;
wait a few seconds, then plug the All-In-
One back in and turn the power on. If the
problem remains, then replace the USB
cable.
Service:
Replace the system board. See
board removal" on page
Technical Support Center:
Replace the All-In-One.
Service:
Replace the scanner assembly. See
"Scanner assembly removal" on
page
4-3.
Technical Support Center:
Unplug the All-In-One from the wall outlet;
wait a few seconds, then plug the All-In-
One back in, and turn the power on. If the
problem remains, then replace the All-In-
One.
Service:
Replace the scanner assembly. See
"Scanner assembly removal" on
page
4-3.
"System
4-26.
"System
4-26.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4443-3024443-3014443-30e4443-303

Table of Contents