Figure 2.21 Primequest 2400E3/2400E2/2400E (High-Efficiency/Standard) 200V Non-Redundant; Figure 2.22 Primequest 2400E3/2400E2/2400E (High-Efficiency/Standard) 200V Redundant (N+1) - Fujitsu PRIMEQUEST 2000 Series Hardware Installation Manual

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 2 Connected Information
(High-efficiency/Standard) 200V Non-redundant
It is necessary to arrange two PSUs, four FANUs, two power cables (200 V IEC60320 C20) and one power
distribution box (200 V IEC60320 C19×3type) for (High-efficiency/Standard) 200V Non-redundant.
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution
panel. See
"2.6 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution

FIGURE 2.21 PRIMEQUEST 2400E3/2400E2/2400E (High-efficiency/Standard) 200V Non-redundant

Number
(1)
(High-efficiency/Standard) 200V Redundant (N+1)
It is necessary to arrange three PSUs, three FANUs, three Power cables (200 V IEC60320 C20) and one
power distribution box (200 V IEC60320 C19×3type) for of (High-efficiency/Standard) 200V Redundant
(N+1).
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution
panel. See
"2.6 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution

FIGURE 2.22 PRIMEQUEST 2400E3/2400E2/2400E (High-efficiency/Standard) 200V Redundant (N+1)

Number
(1)
Power distribution box (200V C 19  3 type)
Power distribution box (200V C 19  3 type)
Description
Description
43
box)."
box)."
CA92344-0535-06