Power On Reset Generator
The power-on reset signals (RESET1P8 and RESET2P8) are asserted based on the VCORE (if VAPPCFG = 0),
VMEM, VEXT, and VPLL regulators. RESET1P8 and RESET2P8 are low when reset is enabled and high when
reset is disabled.
When the outputs of all four regulators reach their corresponding threshold voltages, reset will be disabled
after a nominal reset period of 130ms.
The outputs of all four regulators must remain at or above their corresponding threshold voltages for the
duration of the reset period for reset to be disabled (pulled high).
The nominal 130ms reset period is restarted whenever all four regulators reach their threshold voltages.
The nominal reset period of 130ms can be extended by connecting an external capacitor to CRST. This
capacitor is charged using a small current when reset is enabled. Once the capacitor reaches the threshold,
reset is disabled.
Reset will be enabled immediately if any one of the four regulators falls below their corresponding
threshold voltages. In addition, reset will be enabled if VBAT falls below VRTC. The PWREN signal is the
logical AND of all the state controls that enable or disable many of the regulators on the chip. If the
regulators enabled by PWREN are
disabled by PMT state controls described below then PWREN must go low.
When PWREN goes low reset will be immediately enabled causing RESET1P8 and RESET2P8 to be pulled
low.
When reset is enabled, both RESET1P8 and RESET2P8 are actively pulled low.
CRST is also actively pulled low when reset is enabled.
VABB Regulator Enable/Disable Logic Operation
The VABB regulator powers many on-chip analog circuits on the ABB. The VCXOEN signal, the VABBEn bit
in the LDOControl1 Bit Positions ( Addr 0x35) register, and the AFCDACMode and AFCDACOn bits in the
AuxControl1 Bit Positions ( Addr 0x13) register all particpate in controlling the VABB enable/disable.
When the ABB power management system transitions from Off state, DDLO state, UVLO state, or Thermal
Shutdown State to Power Key Activation, Charger Activation, USB Charger Activation, or Active State VABB
will be enabled. During these state transitions ABBEn = 0 and AFCDACMode = 0, VRF is enabled.
Once the ABB power management system is in Power Key Activation, Charger Activation, USB Charger
Activation, Active-Standby or Active State the VABB regulator enable/disable is controlled by the
information written to the VABBEn and AFCDACMode register bits by system software.
LGE Internal Use Only