PCB DIAGRAM
5-2. Inverter PCB Layout positions
1. PCB Power Supply : Supplies DC 15V and 5V to the inverter circuit for the compressor control.
2. Inverter Control Circuit : Fridge Compressor Control Circuit
3. Bootstrap Charger : This is an independent power circuit for driving the IPM High-Phase IGBT.
4. Current Pickup Circuit : This picks up the currents taken by the Shunt resistance and performs the PWM Duty
control
5. IPM (FNB40560)