Fujitsu AS*9LSACW Service Instructions Manual page 53

Wall mounted type inverter
Table of Contents

Advertisement

0.5 sec
0.1 sec.
Indoor Unit
2 times
blinking
Thermistor
Error
0.5 sec
0.1 sec.
Outdoor Unit
3 times
blinking
Thermistor
Error
0.5 sec
0.1 sec.
Indoor
Unit
4 times
blinking
Controller
Error
0.1
0.5 sec
Room
temperature
sec.
2 times
thermistor defective
blinki
ng
0.1
0.5 sec
Indoor Heat Exchanger
sec.
3 times
Thermistor Error
blinki
ng
0.1
0.5 sec
Discharge
Thermistor
sec.
2 times
Error
blinki
ng
0.1
0.5 sec
Outdoor Heat Exchanger
sec.
3 times
Thermistor Error
blinki
ng
0.1
0.5 sec
Outdoor
Temperature
sec.
4 times
Thermistor Error
blinki
ng
0.1
0.5 sec
Forced
Auto
Switch
sec.
2 times
Error
blinki
ng
The room temperature thermistor detected a abnormal temperature when the power was turned on.
> Remote control does not operate.
[Diagnosis Point]
- Check Thermistor resistance value (Refer to "Thermistor characteristics table").
- Controller PCB defective.
The detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON.
> Remote control does not operate.
[Diagnosis Point]
- Check Thermistor resistance value (Refer to "Thermistor characteristics table").
- Controller PCB defective.
The detection value of the discharge thermistor is either open or shorted
> Compressor, Outdoor Fan : OFF (It automatically releases when the normal value is detected.)
[Diagnosis Point]
- Check Thermistor resistance value (Refer to "Thermistor characteristics table").
- Controller PCB defective.
The detection value of the outdoor heat exchanger thermistor is open.
> Compressor, Outdoor Fan : OFF (It automatically releases when the normal value is detected.)
[Diagnosis Point]
- Check Thermistor resistance value (Refer to "Thermistor characteristics table").
- Controller PCB defective
The detection value of the outdoor temperature thermistor is either open or shorted
> Compressor, Outdoor Fan : OFF (It automatically releases when the normal value is detected.)
[Diagnosis Point]
- Check Thermistor resistance value (Refer to "Thermistor characteristics table").
- Controller PCB defective.
Forced Auto Switch becomes ON for 10 consecutive seconds.
> It indicates the error but the operation continues.
[Diagnosis Point]
- Check if Forced Auto Switch is kept pressed.
- Forced Auto Switch defective.
- Controller PCB defective.