LG -A130 Service Manual page 80

Hide thumbs Also See for LG-A130:
Table of Contents

Advertisement

CHECKING FLOW
SETTING : Enter the engineering mode, and set vibrator on at vibration of BB test menu
START
Check the soldering
of vibrator ?
YES
Is the connection of
TP1 with TP2 connector ok ?
Is I/O Connector(CN102)
well-soldered ?
Is the voltage at
TP4 high?
Is the voltage at
TP3 high?
Replace vibrator
Vibrator
Working well !
Copyright © 2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes
NO
NO
YES
NO
YES
NO
Replace the U102
YES
NO
Replace Main FPCB
YES
YES
- 81 -
4. TROUBLE SHOOTING
4. TROUBLE SHOOTING
Resolder the Pad.
Reassemble FPCB
with Main connector
Resolder the CN102
(PIN20 : F_VIB)
LGE Internal Use Only