NOTE: 1) Indoor fan speed: Hi
2) Vertical adjustment louver "45˚", Horizontal adjustment louver "front"
3) Indoor air temp. : Cooling 27˚C, Heating 20˚C
(Running frequency: 49Hz)
900
800
700
600
2.6
2.4
2.2
2.0
25
30
Outside air temp.(˚C)
Figure P-1. At Cooling for AY-XP08CE
(Running frequency: 62Hz)
1000
900
800
700
3.2
3.0
2.8
2.6
2.4
25
30
Outside air temp.(˚C)
Figure P-2. At Cooling for AY-XP10CE
(Running frequency: 79Hz)
1300
1200
1100
1000
4.0
3.8
3.6
3.4
3.2
25
30
Outside air temp.(˚C)
Figure P-3. At Cooling for AY-XP13CE

PERFORMANCE CURVES

14
12
10
35
40
16
14
12
35
40
14
12
10
35
40
33
(Running frequency: 63Hz)
1000
900
800
700
3.6
3.2
2.8
2.4
-5
0
5
Outside air temp.(˚C)
Figure P-4. At Heating for AY-XP08CE
(Running frequency: 74Hz)
1100
1000
900
800
4.0
3.5
3.0
2.5
-5
0
Outside air temp.(˚C)
Figure P-5. At Heating for AY-XP10CE
(Running frequency: 95Hz)
1600
1500
1400
1300
1200
5.5
5.0
4.5
4.0
3.5
3.0
-5
0
Outside air temp.(˚C)
Figure P-6. At Heating for AY-XP13CE
AY-XP08/10/13CE
AE-X08/10BE-C
AE-X13BE
45
40
35
7
10
45
40
35
30
5
7
10
45
40
35
30
5
7
10