Error Messages And Error Handling; General Information; Error Handling In The Cycles; Overview Of Cycle Alarms - Siemens SINUMERIK 808D ADVANCED Programming And Operating Manual

Operator-panel-based cncs
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

TOLM (Machining types)
This parameter determines which technological machining type is to be used.
9.7

Error messages and error handling

9.7.1

General Information

If error conditions are detected in the cycles, an alarm is generated and the execution of the cycle is aborted.
Furthermore, the cycles display their messages in the message line of the control system. These messages do not interrupt
the program execution.
The errors with their reactions and the messages in the message line of the control system are described in conjunction with
the individual cycles.
9.7.2

Error handling in the cycles

If error conditions are detected in the cycles, an alarm is generated and the machining is aborted.
Alarms with numbers between 61000 and 62999 generated in the cycles. This range of numbers, in turn, is divided again
with regard to alarm responses and cancel criteria.
The error text that is displayed together with the alarm number gives you more detailed information on the error cause.
Alarm number
61000 ... 61999
62000 ... 62999
9.7.3

Overview of cycle alarms

The error numbers are classified as follows:
6
● X=0 General cycle alarms
● X=1 Alarms generated by the drilling, drilling pattern and milling cycles
9.7.4

Messages in the cycles

The cycles display their messages in the message line of the control system. These messages do not interrupt the program
execution.
Messages provide information with regard to a certain behavior of the cycles and with regard to the progress of machining
and are usually kept beyond a machining step or until the end of the cycle. An example of messages is as follows:
"Depth: according to the value for the relative depth" from all drilling cycles.
Programming and Operating Manual (Milling)
6FC5398-4DP10-0BA1, 01/2014
Clearing criterion
NC_RESET
Clear key
_
X
Alarm response
Block preparation in the NC is aborted
The block preparation is interrupted;
the cycle can be continued with the
following key after the alarm has been
cleared:
_
_