Fig. 2.8 Data Transfer Sequence - Epson MX-80 Technical Manual

Hide thumbs Also See for MX-80:
Table of Contents

Advertisement

The data transfer sequence of STROBE and READY signals is shown in Fig. 2.8.
STROBE
DATA
~
I
I
td
Ready set delay
td
<
0.5 p.s
Fig. 2.8 Data Transfer Sequence