Electrical; Millivolt Wiring Diagram - Pentair Pool Products MiniMax CH Operation & Installation Manual

Pool & spa heaters
Hide thumbs Also See for MiniMax CH:
Table of Contents

Advertisement

Installation (contd.)

ELECTRICAL

MiniMax CH Millivolt Wiring Diagram
MINIMAX WIRING DIAGRAM (MILLIVOLT) DUAL THERM
(HONEYWELL ELECTRONIC)
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)
APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE
REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR
SUPERCEDING LOCAL (WIRING) CODES.
TH/PP
TH
PP
GAS VALVE
WHT
ORN
WHT
THERMOSTAT BOARD
NOTE: When connecting a remote control to the MiniMax CH, you must install the low voltage
thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these
instructions will cause the thermostat relay to react
Rev. C 1-22-04
PILOT
GENERATOR
WHT
RED
HI-LIMIT
WHT
POT 1
SAFETY
SWITCH
SHUT-OFF
WHT
POT 2
SENSOR
erratically..
PRESS
WHT
THERMAL
CUT-OFF
WHT
POOL
OFF
SPA
Figure 19.
P/N 472128
17

Advertisement

Table of Contents
loading

Table of Contents