NEC univerge SV9100 Programming Manual page 747

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Issue 4.0
Item
Item
No.
11
T312
Specify the timer value started when
SETUP is sent or re-sent on broadcast
data link. This timer is valid only for
Network side use only.
12
T313
Specify the timer value started when
connection request is sent. Valid range
1 ~ 4 seconds in 1 second increments.
Value of 0 indicates timer not used.
13
T314
Specify the timer value started when
message segment is received.
14
T316
Specify the timer value started when
RESTART is sent.
15
T317
Specify the timer value started when
RESTART is received.
16
T318
Specify the timer value started when
RES is sent. This timer is valid for user
side use only.
17
T319
Specify the timer value started when
SUSPEND is sent. This timer is valid
for user side use only.
18
T320
Specify the timer value when
B-channel access: connection is
received, or D-channel access:
DL-ESTABLISH confirmation or
indication is received.
19
T321
Specify the timer value started when
STATUS ENQ is received.
20
T322
Specify the timer value upon
D-channel failure.
Conditions
None
Feature Cross Reference
ISDN Compatibility
SV9100 Programming Manual
Description
Input Data
1~254 (sec)
1~254 (sec)
1~254 (sec)
(T317+1)~254 (sec)
1~(T316-1)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
Default
6
4
4
120
60
4
4
30
30
4
2-707