Honeywell TH9421C1004 Installation Manual page 4

Visionpro iaq
Hide thumbs Also See for TH9421C1004:

Advertisement

Available languages

Available languages

Installation Guide
Installer setup
Setup function
0372
Indoor humidifica-
tion control
0374
Humidifier fan action 0
0379
Dehumidification
control
0383
Over-cooling limit
0384
Dehumidification
fan action
0390
Dehumidification
away mode
0391
Dehum. away mode
fan setting
0392
Dehum. away mode
low limit temp.
0393
Dehum. away mode
temp. setting
0394
Away dehumidifica-
tion setting
0400
Ventilation control
0401
Number of
bedrooms
0402
Size of house
0403
Ventilation level
0404
Max. ventilation
% limit
0405
Ventilation fan
action
0406
Ventilation in high
humidity
0500
Furnace filter
change alert
69-1816EFS—03
Settings & options (factory default in bold)
E
Auto Discover
0
Off
1
Humidify (no frost protection)
3
Humidify (with frost protection)
Humidify only while fan or heat is on
1
Humidify forces fan on
2
Humidify only when heat is on
3
Humidifier operates independent of fan
0
No dehumidification control
1
Dehumidify with air conditioner
3
Whole house dehumidifier
3
3°F (1.5°C)
[Other options: 1, 2 (1°F or 2°F/0.5°C to 1.5°C)]
0
System fan turns on with dehumidifier
1
Dehumidifier operates independent of fan
0
No
1
Yes
0
Fan auto
1
Fan always on
2
Fan circulate
76
Low limit temperature 76°F (24°C)
[Other options: 70°F to 80°F (21°C to 27°C)]
85
Away temperature 85°F (29°C)
[Other options: 70°F to 99°F (21°C to 37°C)]
65
Away humidity level 65%
[Other options: 55% to 70%]
0
No ventilation
1
Ventilation always allowed
2
Ventilation not allowed during sleep period
2
Two bedrooms
[Other options: 1 to 6]
10
1,000 square feet
[Other options: 11 to 50 (1,100 to 5,000 square feet)]
160 CFM (cubic feet per minute)
[Other options: (30 to 195 CFM)]
50
50% ventilation limit
[Other options: 30% to 60% or 100%]
P
Meets ASHRAE 62.2 standard
F
Does not meet ASHRAE 62.2 standard
1
Ventilation on forces fan on
2
Ventilation does not force fan on
1
On (heat mode only)
0
Off
E
Auto Discover
0
Off
1
10-day run time
2
30-day run time
3
60-day run time
4
90-day run time
5
120-day run time
6
180-day run time

**
**
7
270-day run time
8
365-day run time
9
30 calendar days
10
60 calendar days
11
90 calendar days
12
120 calendar days
13
180 calendar days
14
365 calendar days
**See page 6