Pre-Operation Steps
Before starting the engine, perform the following pre-operation steps:
Check the level of the engine oil and the fuel tank level.
Make sure the air filter is clean.
Remove any debris that has collected on the generator and around the muffler and controls. Use a vacuum cleaner to
pick up loose debris. If dirt is caked on, use a soft bristle brush.
Inspect the work area for hazards.
After Each Use
f
p
Follow the
ollowing
rocedure
Shut off engine.
Charge electric starter. (see Battery Charger for Electric Starter pg 14)
Store unit in a clean and dry area.

Maintenance Schedule

Engine Oil
Check Level
Replace
Air Filter
Check
Clean
Fuel Filter
Replace
Oil Filter
Replace
Fuel Tank
Verify Gas Level
Clean
Changing Oil (See Fig 13)
Run the Generator until the Engine is warm.
Place generator on a level surface.
Remove the crankcase dipstick.
Place an oil pan underneath the oil drainage bolt to collect used oil.
Remove the oil drainage plug and allow oil to drain completely.
Reinstall oil drainage plug, tighten securely.
Carefully add SAE 10W-40 CD to empty reservoir until the oil reaches
the outer edge of the oil fill hole (Crankcase Dipstick hole).
Replace crankcase dipstick.
a
e
u
:
fter
ach
se
Every Month or
Each Use
Each 20 Hrs
O
O(First Use)
O
O
Every 3 Month or
Each 50 Hrs
O
Oil drainage plug
19
Every 12 Month or
Every 6 Month or
Each 300 Hrs
Each 100 Hrs
O
Oil Fill & Dipstick
Fig 13
O
O
O