Adjustment
44
7
719
Sewing foot holding current
720
Cutting holding current
721
Feed converter holding current
722
Acceleration ramp:
1 = flat / 50 = steep
723
Brake ramp:
1 = flat / 50 = steep
729
Start delay after
lowering the sewing foot [ms]
730
Lift delay
for sewing foot after seam end [ms]
731
Stitch count delay for end backtacks
732
Holdoff time for cutting
after simple end backtack [ms]
733
Holdoff time from
switch-on feed reverse
to speed start [ms]
739
Holdoff time for speed
after start backtack or
stitch condensation [ms]
740
Stitch count delay for end backtacks [ms]
760
Stitch count to bobbin thread monitor
(machine stop in needle lowered position)
761
Extension of
thread tension release/
thread tensioning [ms]
791
Stitch count delay
for start backtacks [ms]
797
Hardware test: ON = on / OFF = off
798
User level:
0 = User level A
1 = Mechanic level B
11 = Service level C
B
0 - 50
40
B
0 - 50
40
C
0 - 50
40
C
1 - 50
50
C
4 - 50
50
B
0 - 2550
120
B
0 - 2550
C
0 - 2550
70
C
0 - 2550
30
C
0 - 200
30
C
0 - 2550
200
C
0 - 2550
60
A
0 - 50000
1000
B
0 - 2550
C
0 - 2550
30
B
OFF - ON
OFF
A
0 - 255
0
0
0