13. Position smoke alarm to
Insert pin here
mounting plate and turn
clockwise to lock into place.
(To engage tamper-resist
feature, insert pin into notch
on edge of smoke alarm
after alarm is properly posi-
tioned in base. See instruction 10 on the previous page.)
NOTE: Smoke alarm will not mount to plate if battery is not installed.
14. Turn on power at main fuse box or circuit breaker.
15. Test smoke alarm. See "TESTING THE SMOKE ALARM."
WHITE
WHITE
WHITE
TO NEUTRAL
YELLOW
YELLOW
BLACK
BLACK
BLACK
TO 120 VAC (HOT)
FOR INTERCONNECT: USE # 18 AWG MINIMUM WIRE
INTERCONNECTING SMOKE ALARMS
FOR INTERCONNECT LINE ONLY use #14-#18 AWG minimum
solid or stranded wire. When interconnecting, maximum wire
length between any two is 1,500 feet for #18 AWG or 4,000 feet
for #14 AWG (20 OHMS loop resistance).
This smoke alarm may be interconnected with as many as 11
other Firex model AD, ADC, and FX1218 smoke alarms, or as
many as 6 Firex model ADH heat alarms for a total of not more
than 18 interconnected devices. DO NOT connect to any other
type or model smoke alarm.
Connect smoke alarms to a single AC branch circuit. If local codes
do not permit, be sure the neutral wire is common to both phases.
RED AND GREEN LED INDICATORS
This smoke alarm features separate red and green LED indicators.
The LEDs indicate the following:
GREEN LED
CONSTANT ON
— AC power is present.
OFF
— AC power is not present.
RED LED
— Can be seen through the
Push-to-Test button.
Blinks once a minute
— Indicating presence of a working
battery.
Blinks once a second
— Smoke alarm senses smoke
and simultaneously sounds
an audible alarm.
Blinks once every 10 seconds — Smoke alarm is quieting an
unwanted alarm (Model ADC
only).
(Interconnected system only):
OFF — Another smoke alarm in the network has sensed
smoke and is signalling this alarm.
FALSE ALARM CONTROL™
Model ADC features a False Alarm Control™ that, when activated,
quiets unwanted alarms for up to 15 minutes.
To use the False Alarm Control™:
Press and release the test button during an unwanted alarm. The
alarm should stop within ten seconds. This means the smoke
alarm is in False Alarm Control™. Just before returning to normal
operation, the smoke alarm will sound two short beeps. This sig-
nals the end of False Alarm Control™.
If the smoke alarm does not go into False Alarm Control™ and
continues to sound its loud alarm horn, the smoke is too heavy and
could be a possibly dangerous situation— take emergency action.
TESTING THE SMOKE ALARM
!
W
A
R
N
I
N
G
Test each smoke alarm to be sure it is installed correctly and
operating properly.
Test all smoke alarms in an interconnected system after installation.
The Push-to-Test button accurately tests all functions. DO NOT
use an open flame to test this smoke alarm. You may ignite and
damage the smoke alarm or your home.
5
Test smoke alarms weekly and upon returning from vacation or
when no one has been in the household for several days.
Stand at arm's length from the smoke alarm when testing. The
alarm horn is loud to alert you to an emergency and can be
harmful to hearing.
Test all smoke alarms weekly by doing the following:
1. Observe the green LED. A constant green light indicates the
smoke alarm is receiving 120V AC power.
2. Firmly depress the Push-to-Test button for at least five (5) sec-
onds. The smoke alarm will sound 3 short beeps followed by a
2-second pause and then repeats. The alarm may sound for up
to 10 seconds after releasing the Push-to-Test button.
NOTE: If smoke alarms are interconnected, all smoke alarms
should sound an alarm within three seconds after any test
button is pushed and the tested smoke alarm sounds.
3. If smoke alarm does not sound, turn off power at main fuse box
or circuit breaker and check wiring. Retest smoke alarm.
!
DANGER: If alarm horn sounds, and smoke alarm is not
being tested, the smoke alarm is sensing
smoke. THE SOUND OF THE ALARM HORN
REQUIRES YOUR IMMEDIATE ATTENTION
AND ACTION.
MAINTENANCE AND CLEANING
In addition to weekly testing, this smoke alarm requires yearly battery
replacement and periodic cleaning to remove dust, dirt, and debris.
!
DANGER: ELECTRICAL SHOCK HAZARD. Turn off
power at main service panel by removing
fuse or switching appropriate circuit
breaker to OFF position before replacing
battery or cleaning smoke alarm.
BATTERY REPLACEMENT
Always turn off power to smoke alarm before replacing battery.
Replace battery at least once a year or immediately when the low
battery signal sounds once a minute, even though the smoke
alarm is receiving AC power. Batteries should be replaced regu-
larly as necessary, even when the smoke alarm is receiving AC
power.
Use only the following batteries as replacements in this smoke alarm:
Eveready 216, 522, 1222, Duracell MN 1604 or Ultralife U9VL-J
!
WARNING: DO NOT USE ANY OTHER TYPE OF BAT-
TERY, EXCEPT AS SPECIFIED IN THIS
MANUAL. DO NOT USE RECHARGEABLE
BATTERIES.
1. Turn off power to smoke alarm at main service panel.
2. Turn smoke alarm counterclockwise to detach from mounting plate.
3. Gently pull down smoke alarm. Be careful not to separate wire
connections.
4. Pull out power plug from back of smoke alarm.
5. From back of smoke alarm, lift tab to open battery pocket door.
6. Remove battery from pocket. Disconnect and discard drained
battery from battery connector.
7. Connect a fresh, 9-volt battery to connector. The battery will fit
only one way. Be sure battery connector is securely attached
to battery terminals.
8. Place battery into battery pocket.
9. Close battery pocket door. Push down until it snaps into place.
10. Replace connector plug. Connector will snap into place. Gently
tug connector to be sure it is attached properly.
11. Reattach smoke alarm to mounting plate by turning smoke
alarm clockwise until it snaps into plate.
12. Turn on power and test smoke alarm using Push-to-Test button.
CLEANING
Clean the smoke alarm at least once a month to remove dust,
dirt, or debris. Always turn off power to smoke alarm before cleaning.
Using the soft brush or wand attachment to a vacuum cleaner,
vacuum all sides and cover of smoke alarm. Be sure all the
vents are free of debris.
If necessary, turn off power and use a damp cloth to clean
smoke alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the
smoke alarm. THIS WILL VOID YOUR WARRANTY.
6
REPAIR
CAUTION: Do not attempt to repair this smoke alarm.
Doing so will void your warranty.
If smoke alarm is not operating properly, see "TROUBLESHOOTING".
If necessary and if still under warranty, return smoke alarm to
Maple Chase Company. Pack it in a well-padded carton, shipping
prepaid, to:
Maple Chase Company
Product Service Department
2820 Thatcher Road
Downers Grove, IL 60515-4040
If the smoke alarm is no longer under warranty, have a licensed
electrician replace the smoke alarm immediately with a compar-
able Firex brand smoke alarm.
PRACTICE FIRE SAFETY
If the smoke alarm sounds its alarm horn, and you have not
pushed the test button, it is warning of a dangerous situation.
Your immediate response is necessary. To prepare for such
occurrences, develop family escape plans, discuss them with
ALL household members, and practice them regularly.
Expose everyone to the sound of a smoke alarm and explain
what the sound means.
Determine TWO exits from each room and an escape route to
the outside from each exit.
Teach all household members to touch the door and use an
alternate exit if the door is hot. INSTRUCT THEM NOT TO
OPEN THE DOOR IF THE DOOR IS HOT.
Teach household members to crawl along the floor to stay below
dangerous smoke, fumes, and gases.
Determine a safe meeting place for all members outside the
building.
WHAT TO DO IN CASE OF A FIRE
1. Don't panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to
feel if they are hot before opening them. Use an alternate
exit if necessary. Crawl along the floor, and DO NOT stop
to collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire department from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for
the fire department to arrive.
These guidelines will assist you in the event of a fire. However, to
reduce the chance that fires will start, practice fire safety rules
and prevent hazardous situations.
7
TROUBLESHOOTING
!
DANGER:
Always turn off power at main fuse box
or circuit breaker before taking trouble-
shooting action.
!
WARNING:
DO NOT disconnect battery or AC
power to quiet an unwanted alarm.
This will remove your protection. Fan
the air or open a window to remove
smoke or dust.
PROBLEM
SOLUTION
Smoke alarm does not
1. Check that AC power
sound when tested.
is turned on.
2. Turn off power. Remove
smoke alarm from
NOTE: Push test button for
mounting plate and:
at least five (5) seconds
a. check that connector
while testing!
plug is securely
attached.
b. check that battery is
properly attached to
connector.
3. Clean smoke alarm.
Smoke alarm beeps about
1. Turn off power and
once a minute.
replace battery. See
"Battery Replacement"
in the "MAINTENANCE
AND CLEANING" section.
Smoke alarm sounds
1. Clean smoke alarm.
unwanted alarms intermit-
See "Cleaning" in the
tently or when residents
"MAINTENANCE AND
are cooking, taking
CLEANING" section
showers, etc.
2. Hire an electrician to
move smoke alarm to
a new location. See
"SMOKE ALARM
PLACEMENT"
Interconnected smoke
1. Press and hold test
alarms do not sound when
button for at least
system is tested.
three seconds after
the first unit sounds.
The alarm sounds different
1. The alarm is operating cor-
than I'm used to. It starts and
rectly. This alarm features
stops.
the internationally recog-
nized horn signal for evacu-
ation. The horn pattern is 3
short beeps followed by a 2
second pause and then
repeats.
WARRANTY INFORMATION
5-YEAR LIMITED SMOKE ALARM WARRANTY AND
10-YEAR LIMITED ULTRALIFE U9VL-J LITHIUM BATTERY WARRANTY
(WHEN SOLD WITH MAPLE CHASE COMPANY SMOKE ALARM)
Maple Chase Company warrants to the original consumer purchaser each new smoke
alarm to be free from defects in material and workmanship under normal use and service
for a period of five (5) years from the date of purchase. For Maple Chase Company smoke
alarms sold with an Ultralife U9VL-J 9-volt battery, Maple Chase Company warrants to the
original consumer purchaser each new Ultralife U9VL-J 9-volt battery to be free from
defects in material and workmanship under normal use and service for a period of ten (10)
years from the date of purchase. Maple Chase Company agrees to repair or replace, at
its option, any defective smoke alarm or Ultralife U9VL-J 9-volt battery (when sold with
Maple Chase smoke alarm) provided that it is returned with postage prepaid and with
proof of purchase date to Maple Chase Company. This warranty does not cover damage
resulting from accident, misuse or abuse or lack of reasonable care of the product. This
warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
LIMITED TO A PERIOD OF FIVE (5) YEARS FOR THE SMOKE ALARM AND TEN (10) YEARS
FOR THE ULTRALIFE LITHIUM U9VL-J 9-VOLT BATTERY (WHEN SOLD WITH MAPLE
CHASE SMOKE ALARM) FROM PURCHASE DATE. Some states do not allow limitations on
how long an implied warranty lasts, so the above limitations may not apply to you. IN NO
CASE SHALL MAPLE CHASE COMPANY BE LIABLE FOR ANY INCIDENTAL OR CONSE-
QUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR
IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLI-
GENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or con-
sequential damages, so the above limitation or exclusion may not apply to you. This war-
ranty gives you specific legal rights, and you may also have other legal rights which vary
from state to state.
This smoke alarm's manufacture and distribution are licensed by the U.S. Nuclear
Regulatory Commission.
This product meets all the requirements of U.L. Standard 217.