Configure The Fc-Map Value; Configure A Port For A Bridge-To-Bridge Link; Configure A Port For A Bridge-To-Fcf Link; Impact On Other Software Features - Dell Z9500 Configuration Manual

Z-series core and aggregation switche
Hide thumbs Also See for Z9500:
Table of Contents

Advertisement

A maximum of eight VLANS are supported for FIP snooping on the switch. When enabled globally, FIP snooping processes
FIP packets in traffic only from the first eight incoming VLANs. When enabled on a per-VLAN basis, FIP snooping is
supported on up to eight VLANs.

Configure the FC-MAP Value

You can configure the FC-MAP value to be applied globally by the switch on all or individual FCoE VLANs to authorize FCoE
traffic.
The configured FC-MAP value is used to check the FC-MAP value for the MAC address assigned to ENodes in incoming FCoE
frames. If the FC-MAP value does not match, FCoE frames are dropped. A session between an ENode and an FCF is established
by the switch-bridge only when the FC-MAP value on the FCF matches the FC-MAP value on the FIP snooping bridge.

Configure a Port for a Bridge-to-Bridge Link

If a switch port is connected to another FIP snooping bridge, configure the FCoE-Trusted Port mode for bridge-bridge links.
Initially, all FCoE traffic is blocked. Only FIP frames with the ALL_FCF_MAC and ALL_ENODE_MAC values in their headers are
allowed to pass. After the switch learns the MAC address of a connected FCF, it allows FIP frames destined to or received from
the FCF MAC address.
FCoE traffic is allowed on the port only after the switch learns the FC-MAP value associated with the specified FCF MAC
address and verifies that it matches the configured FC-MAP value for the FCoE VLAN.

Configure a Port for a Bridge-to-FCF Link

If a port is directly connected to an FCF, configure the port mode as FCF. Initially, all FCoE traffic is blocked; only FIP frames are
allowed to pass.
FCoE traffic is allowed on the port only after a successful fabric login (FLOGI) request/response and confirmed use of the
configured FC-MAP value for the VLAN.
FLOGI and fabric discovery (FDISC) request/response packets are trapped to the CPU. They are forwarded after the necessary
ACLs are installed.

Impact on Other Software Features

When you enable FIP snooping on a switch, other software features are impacted. The following table lists the impact of FIP
snooping.
Table 28. Impact of Enabling FIP Snooping
Impact
MAC address learning
MTU auto-configuration
Link aggregation group (LAG)
STP
Description
MAC address learning is not performed on FIP and FCoE
frames, which are denied by ACLs dynamically created by FIP
snooping on server-facing ports in ENode mode.
MTU size is set to mini-jumbo (2500 bytes) when a port is in
Switchport mode, the FIP snooping feature is enabled on the
switch, and FIP snooping is enabled on all or individual VLANs.
FIP snooping is supported on port channels on ports on
which PFC mode is on (PFC is operationally up).
If you enable an STP protocol (STP, RSTP, PVSTP, or MSTP) on
the switch and ports enter a blocking state, when the state
FIP Snooping
337