27. hoW to purge the dhW system from limestone deposits

To clean the DHW system it is not necessary to remove the DHW heat ex­changer if the assembly is equipped with the
appropriate taps (supplied on demand) placed on the hot water outlet and inlet.
To carry out the purge it is necessary to:
• close the cold water inlet
• drain the DHW system from the water contained therein by means of a hot water tap
• close the DHW outlet
• unscrew the two stop cocks caps
• remove the filters.
In case the appropriate tap is not supplied it is necessary to disassemble the DHW heat ex­changer, as described in the fol-
lowing section, and do the purge aside. We recommend you also purge from limestone deposits the DHW heat ex­changer
seat and the NTC sensor fitted on the DHW system.
To purge the ex­changer and/or the DHW system we suggest the use of Cillit FFW-AL or Beckinser HF-AL.

28. hoW to disassemble the dhW heat exchanger

The stainless steel plate-type DHW heat ex­changer is easily disassembled with a screwdriver by operating as described
below:
• drain, if possible, only the boiler system, through the drain tap;
• drain the DHW system from water;
• remove the two screws (right in front of you) securing the DHW heat ex­changer and pull it off its seat (figure 19).

29. cleaning the cold Water filter

The boiler is equipped with a cold water filter placed on the hydraulic assembly. To clean it do the following:
• drain the DHW system from water;
• unscrew the nut on the flow sensing assembly (Figure 19);
• pull out the flow sensing device and its filter;
• remove the impurities.
important: in the event of replacements and/or cleaning of the O-rings on the hydraulic unit, do not use oil or grease as
lubricant but ex­clusively Molykote 111.
flow sensing securing nut
Figure 19
DHW heat ex­changer securing screws