Special Functions - Baxi LUNA 3 COMFORT MAX Installers And Users Instructions

High efficiency wall-mounted gas-fired boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 41
This function enables the user to set two different room temperature setpoints:
economy / comfort.
For more simplicity it's better to set the COMFORT value temperature higher than the ECONOMY value temperature.
To set the required room temperature, press the
the "econM" writing shows the operating in reduced room temperature mode;
display shows
symbol;
the "coMFr" writing shows the operating in nominal room temperature mode;
display shows
symbol;
To temporary change the setting room temperature value, press
This function could operates in automatic or in manual mode:
autoMatic operation (displayed symbol
The setting room temperature depends on the time slot (section 3.6). Inside the time slot the room temperature is the
COMFORT value, outside the time slot the room temperature is the ECONM value.
To temporary change the room temperature value (from COMFORT to ECONOMY or vice versa) press the
ton. This changes has effect until the nex­t time change over.
Manual operation (displayed symbol
Press
button to set the gas boiler in manual operation mode
To temporary change the room temperature value (from COMFORT to ECONOMY or vice versa) press the
ton. This change has effect until the nex­t button pressure.
The shower function ensures better hot water comfort, e.g. during a shower.
This function enables domestic hot water to be drawn at a lower temperature than the nominal temperature value.
To set or modify the max­. shower function temperature value, refer to section 4.3.
This function can be manually activated in the following way:
• Press one of the two buttons +/-
(the message shoWr briefly appears on the display, followed by the message hW ss);
• press the oK button while the flow temperature and the symbol
• the duration of the function is 60 minutes (during this time the symbol
At the end of this time the domestic hot water temperature returns to the value of the previously set operating mode
(the symbol
is no longer intermittent on the display).
note: To disable the function before the end of the 60 minutes, proceed as follows:
• press one of the two buttons +/-
press the oK button, the display shows the message "hW s^
instructions pertaininG to the user

4. special functions

4.1 economy - comfort function
)
)
4.2 shoWer function
and then the button
and then the button
button:
+/-
buttons or see section 4.3.
to activate the function;
flash on the display;
flashes).
;
"..
48
but-
but-
925.480.1 - GB