Test 4 Moisture Sensor - LG DLE1501W Service Manual

Electric & gas dryer
Table of Contents

Advertisement

Test 4
Moisture sensor
Caution
Trouble Symptom
Measurement Condition
Take NA6 Connector from
the Controller.
Metal or Wire
Dampi n gcl o th
Table 2. IMC Ratio and Display Value / Voltage (IMC: Initial Moisture Content)
IMC
70% ~ 40%
40% ~ 20%
10% ~ Dried clothes
efore measuring resistance, be sure to turn power off, and do voltage discharge.
(When discharging, contact the metal plug of power cord with ground line.)
Degree of dryness does not match with dry Level.
Turn the dryer’s power off, then measure resistance.
Short with metal to the 6 pin connector’s
Pin (Orange Wire) and Pin (Red Wire) to controller.
When measuring resistance in electric load,
is resistance below 1
When contacting cloth to electro load:
1.Is the measurement within the range of Table 2
during Diagnostic Test?
2.Is the measurement within the range of Table 2
when measuring the voltage in the NA6 connector’s
Pin (Orange wire) and Pin ( lue wire)?
Normal Condition
Voltage (DC) (between NA6 terminal , )
Display Value
50 ~ 130
130 ~ 20
205 ~ 240
?
YES
YES
2.5V
2.0V ~ 4.0V
Over 4.0V
24
• Check electro Load
and harness
O
connector
• Check harness-
linking connector.
• Replace control
O
and check.
Remark
Weight after removing from
washing machine
Damp dry
Completely-dried clothes

Hide quick links: