ROUGH IN DIMENSIONS

MODEL
XWH 150
XWH 200
XWH 285
XWH 400
XWH 500
XWH 600
XWH 700
XWH 800
GAS LINE CONNECTION SIZE
† MODEL
SERIES
XWH 150
100
XWH 200
100
XWH 285
100
XWH 400
100
XWH 500
100
XWH 600
100
XWH 700
100
XWH 800
100
† Depending on the installed equivalent length, and/or the number of appliances connected,
the supply gas line size may have to be increased beyond the minimum required sizes - see
Table 23 on Page 44.
GAS PRESSURE REQUIREMENTS
*MANIFOLD PRESSURE
MODEL
NATURAL GAS
XWH 150 -0.22" W.C. (-0.054 kPa) -0.23" W.C. (-0.057 kPa)
XWH 200 -0.39" W.C. (-0.09 kPa)
XWH 285 -0.68" W.C. (-0.17 kPa)
XWH 400 -1.45" W.C. (-0.36 kPa)
XWH 500 -0.20" W.C. (-0.05 kPa)
XWH 600 -2.17" W.C. (-0.54 kPa)
XWH 700 -2.97" W.C. (-0.74 kPa)
XWH 800 -3.50" W.C. (-0.88 kPa)
* The manifold pressure is the factory setting and is not adjustable. A negative pressure will be seen with just the blower running without the Gas Control Valve open.
ELECTRICAL REQUIREMENTS
Model
Voltage/ Heater Voltage/ Pump
XWH 150
XWH 200
XWH 285
XWH 400
XWH 500
XWH 600
XWH 700
XWH 800

INSTALLATION CONSIDERATIONS

HEIGHT
INCHES (CM)
33-1/4" (84.5)
33-1/4" (84.5)
42-1/2" (107.95)
42-1/2" (107.95)
42-1/2" (107.95)
42-1/2" (107.95)
42-1/2" (107.95)
42-1/2" (107.95)
TABLE 2
NATURAL GAS
PROPANE GAS
NPT
NPT
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
1"
1"
1"
1"
1"
PROPANE GAS
-0.39" W.C. (-0.09 kPa)
-0.71" W.C. (-0.18 kPa)
-1.40" W.C. (-0.35 kPa)
-0.20" W.C. (-0.05 kPa)
-2.72" W.C. (-0.67 kPa)
-3.58" W.C. (-0.89 kPa)
-4.30" W.C. (-1.1 kPa)
Voltage/ Control
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
TABLE 1
DIMENSIONS
WIDTH
INCHES (CM)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
15-1/2" (39.4)
STORAGE CAPACITIES
MODEL
XWH 150
XWH 200
XWH 285
XWH 400
1"
XWH 500
XWH 600
1"
XWH 700
1"
XWH 800
1"
1"
TABLE 4
MINIMUM SUPPLY PRESSURE
NATURAL GAS
PROPANE GAS
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
4" W. C. (1 kPa)
8" W. C. (2 kPa)
TABLE 5
Total AMPS W/ Pump
24
3.0
24
3.2
24
4.5
24
6.5
24
5.7
24
5.7
24
12.8
24
12.8
10
DEPTH
INCHES (CM)
18" (45.72)
22-1/4" (56.5)
19-3/4" (50.2)
27" (68.6)
31-1/4" (79.4)
36-1/4" (92.1)
40-1/4" (102.2)
42-1/4" (107.3)
TABLE 3
U. S. GALLONS
LITERS
1.3
4.9
1.7
6.4
2.4
9.1
3.4
12.9
4.2
15.9
4.2
15.9
5.0
18.9
5.7
21.6
MAXIMUM SUPPLY PRESSURE
NATURAL GAS
PROPANE GAS
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa 14" W. C. (3.49 kPa)
14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
# Of Electrical Connections
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xwh 2150Xwh 800

Table of Contents