Fluid Supply

Solvent Meter Accessory

The ProMix 2KS Solvent Push feature requires installa-
tion of the accessory solvent meter (MS). Order Graco
Part No. 280555 S3000 Solvent Meter Kit. See manual
308778.
NOTE: You must assemble the meter sensor to the
meter body before connecting the cable to the sensor
for the meter to function properly.
1. See F
. 11. Install the solvent meter (MS) on the
IG
side of the fluid station, using the bracket and hard-
ware provided with the meter. Connect the solvent
meter cable (SMC) to Pins 1, 2, and 3 of J12 on the
fluid panel control board. See the System Electri-
cal Schematic on page 33. Connect the cable
ground wire to the fluid station ground terminal.
Key:
MS
Solvent Meter (accessory)
SPV Solvent Purge Valve
SMC Solvent Meter Cable
SS
Solvent Supply Line
F
. 11. Solvent Meter
IG
22
2. Connect a solvent supply line (SS) from the outlet of
the solvent meter (MS) to the inlet of the solvent
purge valve (SPV).
NOTE: If you are using a 3rd purge valve instead of the
solvent purge valve to run the Solvent Push feature,
connect the solvent supply line from the solvent meter to
the inlet of the 3rd purge valve.
3. Connect the main solvent supply to the inlet of the
solvent meter (MS).
SS
MS
SMC
TI12556b
SPV
312775J