ELECTRICAL ACCESSORIES

Connection cable
GZL 1019 A1
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 1 m.
Connection cable
GZL 1019 A5
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 5 m.
Connection cable
GZL 1019 A10
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 10 m.
BNC coupler
GZV 1019
For connecting two connection cables GZL 1019 A1, -5, -10.
N.B.: „INFRA-RED
If you consider using a transmission system with high power IR radiators
PLANNING BROCHURE"
SZI 1029 the „Infra-red Planning Brochure" from Sennheiser is available.

FROM SENNHEISER

Besides in-depth information on infra-red transmission technology it
contains application examples and lists with combinations and overviews
for infra-red system planning.
Since we are continually trying to improve our products it may happen
that some technical alterations are made on the described products after
these operating instructions have gone to press. We apologise for any
inconvenience.
38
SZI 1029 (SZI 1029-10)

TECHNICAL SPECIFICATIONS

Number of radiator diodes
Approximate radiating power
Wavelength of radiated
infra-red light approx.
Carrier frequency range
IR input
Input/output connections
Switching treshold for
automatic on/off function
Operating voltage
Current consumption ...-120
Stand-by
Mains fuse for 120/230/240 V
Fuse for 24 V
Dimensions in mm
Weight
Supply schedule
UL-No. (only for 120 volt
USA version)
144 (288)
5 W (10 W)
880 nm
30 kHz - 6 MHz
50 mV - 3 V / approx. 5 kΩ
BNC sockets
50 mV
...-120
85 - 265 V ± 10 %, 50 - 60 Hz
...-EU
85 - 265 V ± 10 %, 50 - 60 Hz
...-UK
85 - 265 V ± 10 %, 50 - 60 Hz
...-24
24 V min., ideally 25 - 35 V DC
approx. 610 mA (1A) with 120 V
...-EU approx. 350 mA (700 mA) with 230 V
...-UK approx. 350 mA (700 mA) with 240 V
...-24
approx. 1.6 A (3.2 A) with 24 V DC
60 mA max.
2 A, anti-surge type
in the IEC mains socket
DC 2 A, anti-surge type
250 x 180 x 80 (250 x 288 x 80)
approx. 2.1 kg (approx. 3 kg)
1 radiator
1 mains cable (2.5 m)
to be advised
39