Before Calling For Service - Worcester waaiu5 Operation Manual

Green source air / air heat pump
Hide thumbs Also See for waaiu5:
Table of Contents

Advertisement

BEFORE CALLING FOR SERVICE

The following conditions do not denote equip-
ment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on
immediately after it is turned off. The unit will not
operate immediately after the mode is changed.
This is to protect the internal mechanisms. Wait 3
minutes before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the unit
may be sent out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound
is generated by the friction of the front panel and
other components expanding or connecting due to
a temperature change.
A LOW BUZZING NOISE EMITTED
This is a sound emitted when the unit is generating
Plasmacluster ions.
SWISHING NOISE
The soft, swishing noise is the sound of the
refrigerant fl owing inside the unit.
WATER VAPOUR
• In the COOL and DRY operation, water vapour
can sometimes be seen at the air outlet due to the
difference between the room air temperature and
the air discharged by the unit.
• In the HEAT operation, water vapour may fl ow out
of the outdoor unit during de-icing.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit will
rotate its' fan for about a minute to cool down the
unit.
ODOR EMITTED FROM THE PLASMACLUSTER
AIR OUTLET
This is the smell of ozone generated from
the Plasmacluster Ion generator. The ozone
concentration is very small, posing no adverse
effect on your health. The ozone discharged into the
air rapidly decomposes, and its density in the room
will not increase.
If the unit appears to be malfunctioning, check
the following points before calling for service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the
fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE
ROOM EFFECTIVELY
• Check the fi lters. If dirty, clean them.
• Check the outdoor unit to make sure nothing is
blocking the air inlet or outlet.
• Check the thermostat is proper setting.
• Make sure windows and doors are closed tightly.
• A large number of people in the room can prevent
the unit from achieving the desired temperature.
• Check whether any heat-generating appliances
are operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE
CONTROL SIGNAL
• Check whether the remote control batteries have
become old and weak.
• Try to send the signal again with the remote
control pointed properly towards the unit's signal
receiver window.
• Check whether the remote control batteries are
installed with the polarities properly aligned.
Please call for service when OPERATION lamp,
TIMER lamp and/or PLASMACLUSTER lamp on
the unit blink.