Measuring
Item
instrument
PDP POWER
Signal generator
VOLTAGE
[35V]
DC voltmeter
MAIN POWER UNIT voltage adjustment point
CN0C4
1. Vs
2. NC
3. Va(Vd)
4. NC
5. 5V
6. GND
CN0C4
Vs
NC
Va
NC
5V
GND
Vs value Va(Vd) value
Voltage label
( sxxxx / dxxx ) xxx / xxx / xxx
xxx / xxx / xxx / xxx
xx / xx / xx / xx / xx
xxxxxxx
1-36 (No.YA101)
Test point
Adjustment part
Connector
Vs VR:190V ADJ
CN0C4
(R1551)
Vs
Va VR:60V ADJ
Va(Vd)
(R1451)
[MAIN POWER
[MAIN POWER UNIT]
UNIT]
Vs
Va(Vd)
Voltage adjustment VR
Fig. 4
1
2
3
Vs
4
Va
5
6
Fig. 5
MAIN POWER UNIT
Fig. 6
Description
CAUTION:
During adjustment operation of PDP POWER VOLTAGE,
don't touch the heat sink of the MAIN POWER UNIT. If
you touch it, electric shock may be caused.
< When MAIN POWER UNIT is not replaced >
(1) Connect the DC voltmeter to the CN0C4 connector
and turn on the power. (See Fig.5)
(2) Adjust Vs (190V ADJ) VR and Va (60V ADJ) VR so that
the Vs and Va voltage coincides with the values in the
voltage label.
(3) Input a PAL all-black signal and check that it coincides
with the values in the voltage label.
(4) Readjust if the adjusted value is different from those
in the voltage label.
NOTE:
Designed value for the panel is printed on a label on the
upper-left at the back of the PDP. (See Fig.6)
< When MAIN POWER UNIT is replaced >
CAUTION:
Before making adjustments, be sure not to turn on the
power when the CN8003 and CN8005 connectors are
connected, as this may cause the PDP to break down.
(1) Disconnect the CN8003 and CN8005 connectors on
the MAIN POWER UNIT.
(2) Connect DC voltmeter to the CN0C4 connector and
turn on the power. (See Fig.5)
(3) Adjust Vs (190V ADJ) VR and Va (70V ADJ) VR so that
the Vs and Va voltage coincides with the values in the
voltage label.
(4) Turn off the power, and connect the CN8003 and
CN8005 connectors and turn on the power again.
(5) Input a PAL all-black signal and check that it coincides
with the values in the voltage label.
(6) If the adjusted value is different from those in the
voltage label, fine-tune without unplugging the
connectors.
CAUTION:
Designated power supply voltage of the panel (Vs, Va)
varies according to the PDP unit.
Pay careful attention during adjustment, as any error in
procedure may cause the PDP to break down.