When not using antenna connectors on the OAP433e, keep the covers securely attached for weather
protection. Once the AP is deployed, these unused connectors must be properly terminated.
Equipment shall be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the
Canadian Electrical Code, Part 1, and when applicable, the National Electrical Safety Code, IEEE C2.
Equipment shall be properly grounded according to Chapter 8 of ANSI/NFPA 70, the National Electrical
Code (NEC) and the Cable distribution system should be grounded (earthed) in accordance with ANSI/
NFPA 70, the National Electrical Code (NEC), in particular Section 820.93, Grounding of the Outer
Conductive Shield of a Coaxial Cable.
The separate protective earthing terminal provided on this product shall be permanently connected to
earth.
Approved Antennas for OAP433e
Only approved antennas may be used in conjunction with OAP433e access points. Access
Points have been designed to operate with the antennas listed below. Antennas not included
Approved Antennas for OAP433e
Grounding Holes