Panasonic AW-HB505 Operating Instructions Manual

Multiport hub

Advertisement

Quick Links

Multiport Hub
AW-HB505
Before attempting to connect or operate this product,
please read these instructions completely.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AW-HB505

  • Page 1 Multiport Hub AW-HB505 Before attempting to connect or operate this product, please read these instructions completely.
  • Page 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SER- VICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PER- SONNEL. The lightning flash with arrowhead sym- bol, within an equilateral triangle, is intended to alert the user to the pres- ence of uninsulated "dangerous voltage"...
  • Page 3: Table Of Contents

    FEATURES ... 2 PRECAUTIONS ... 3 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ... 4 FRONT PANEL ... 4 REAR PANEL ... 6 INSTALLATION OF PAN/TILT HEAD ... 8 CONNECTION ... 11 OPERATION ... 15 RACK MOUNTING ... 23 SPECIFICATIONS ... 24 ACCESORIES ...
  • Page 4: Features

    FEATURES • The Multiport Hub AW-HB505 is combined with the Multi-Hybrid Control Panel (AW-RP505) to control up to five Pan/tilt Heads (AW-PH300) and Color Video Cameras (AW-E560). When the Multiport Hub AW- HB505 is connected to the Multi-Hybrid Control Panel...
  • Page 5: Precautions

    • Switch power off before power cable connection or disconnection. Be sure to switch power off before connecting or dis- connecting the power cable. • Avoid outdoor use. • Install the control panel more than 1 meter away from the monitors.
  • Page 6: Major Operating Controls And Their Functions

    C A B L E C O M P cator lights.) The camera and pan/tilt head are partial- ly switched off when this switch is set to the OFF posi- tion. Note: This switch must be set to the ON position in advance in controlling the cameras and pan/tilt heads from the Multi-Hybrid Control Panel.
  • Page 7 Control Switch on the Multi- Hybrid Control Panel, and set the Camera Control Switch to the ON position. Set the MODE Switch on the Multi-Hybrid Control Panel to BAR, then output color bar signals from the camera, and connect a waveform monitor or vectorscope, for example, to the video out- put.
  • Page 8: Rear Panel

    REAR PANEL VIDEO VIDEO PAM/TILT CONTROL OUT CONTROL OUT S-VIDEO OUT VIDEO OUT VIDEO OUT CAMERA CAMERA CONTROL OUT CONTROL OUT t 12V DC Input Connector [DC 12V IN] (4-pin Cannon Connector) Connect the AC Adaptor AW-PS505 (optional accesso- ry). y Pan/tilt Control Input Connector [TO CONTROL PANEL, PAN/TILT HEAD, CONTOROL IN] (RJ-45 8-pin Modular Jack)
  • Page 9 o Camera Control Input Connector [TO CONTROL PANEL, CAMERA CONTROL IN] Connect it to Camera Control Input Connector [CAM- ERA CONTROL OUT] on the multi hybrid control panel with a coaxial straight cable (5C-2V or equivalent), which may be extended up to 10 meters. !0 Pan/tilt Control Output Connector [TO CAMERA PAN/TILT HEAD, PAN/TILT CONTOROL OUT] (RJ- 45 8-pin Modular Jack)
  • Page 10: Installation Of Pan/Tilt Head

    If the pan/tilt head is mounted on a board, for example, be sure to shift the mounting direction switch- es on the pan/tilt head. Unless this is done, pan/tilt directions will be reversed and pan/head operation lim- iter data cannot be properly stored in the memory.
  • Page 11 If the distance between the pan/tilt head and the control panel is shorter than 300 meters, keep the switch in the original position (OFF). For details on shifting the switch, refer to the figure below or the Operating Instructions for Pan/tilt Head. DESKTOP...
  • Page 12 If the distance from the control panel to the pan/tilt head is longer than 300 meters, set the cable compen- sation switch to the ON position by observing the fol- lowing procedure. q Remove the controller connection panel from the pan/tilt head.
  • Page 13: Connection

    CONNECTION • Before making any connection, switch off all the com- ponents of the system. • Use the Control Panel AC Adaptor AW-PS301 (optional) and Pan/tilt Head AC Adaptor AW-PS300 (optional). Cord Clamper DC Cord Control Panel AC Adaptor AW-PS301 •...
  • Page 14 • Connect the iris control cable of the motor-driven zoom lens to the camera and the remote (zoom/focus control) cable to the pan/tilt head. If the remote (zoom/focus control) cable of the motor-driven zoom lens is con- nected to the camera, the lens cannot be controlled. Remote (Zoom/Focus Control) Cable Iris Control Cable...
  • Page 15 S-VIDEO OUT S-VIDEO OUT S-VIDEO OUT VIDEO OUT VIDEO OUT VIDEO OUT CAMERA CAMERA CAMERA CAMERA CONTROL OUT CONTROL OUT CONTROL OUT CONTROL IN D C 1 2 V S E E M A N U A L Multiport Hub AW-HB505...
  • Page 16 Color Monitor WV-CM CAMERA CONTROL C A B L E C O M P P O W E R O F F Multiport Hub PREVIEW AW-HB505 PAN/TILT VIDEO CONTROL SYSTEM TALLY CAMERA CONTROL M u l t i H y b r i d C o n t r o l P a n e l A W - R P 5 0 5...
  • Page 17: Operation

    Down titing memory limitor switch q Select a pan/tilt head with the CONTROL switch on the multi hybrid control panel. w Left Panning Limiter Turn the pan/tilt head to the desired left panning limit with PAN/TILT Lever of the multi hybrid control panel,...
  • Page 18 PAN/TILT Lever of the multi hybrid control panel, keep MEMORY Switch depressed, and simultaneously press buttons [4] and [9] of PRESET Switch for 5 sec- onds or more. When the desired limit has been set, button [5] of PRESET Switch lights.
  • Page 19 If the cable length from the pan/tilt head to the control panel is longer than 300 meters, set the cable com- pensation switch on the pan/tilt head to the ON posi- tion. For details, refer to INSTALLATION OF PAN/TILT HEAD at page 8 or the Operating Instructions for Pan/tilt Head.
  • Page 20 No G/L adjustment is necessary in case of no genlock. • Horizontal Phase Adjustment q Set G/L PHASE ON/OFF Switch of the multi hybrid con- trol panel to the ON position. Note: When G/L PHASE ON/OFF Switch of the multi...
  • Page 21 0 ° 2 7 0 ° O F F e Set G/L PHASE ON/OFF Switch of the multi hybrid con- trol panel back to the OFF position. Subcarrier Phase Adjustment q Set G/L PHASE ON/OFF Switch (15) of the multi hybrid control panel to the ON position.
  • Page 22 3) Set the switches for gain, shutter, etc. as appropriate to the conditions of using the camera. 4) Set the camera control switch on the multi hybrid con- trol panel to the OFF position. 5) Repeat Steps 1 to 4 to finish cable compensation, G/L adjustment, total pedestal adjustment, and switch set- ting for all the cameras.
  • Page 23 Be careful to keep a shiny or bright object out of the screen. e When AWC Switch of the multi hybrid control panel is pressed, the auto Auto set Indicator flashes and the white balance is automatically adjusted.
  • Page 24 Select a white balance con- trol mode using AUTO/ATW ATW Switch AUTO/ATW A Switch or AUTO/ATW B Switch. To store iris data in the memory, set IRIS AUTO/MANU Switch to the MANU position and turn the iris control.
  • Page 25: Rack Mounting

    To mount the multiport hub in a rack, use the supplied rack mounting brackets and screws (M4x10). q Press the power switch to turn power off. w Remove the 4 feet. e With the rack mounting brackets on both ends of the multiport hub, fasten them with the supplied screws (4 pcs.)
  • Page 26: Specifications

    75Ω x 5 (BNC connector) Control signal x 5 (BNC connector) Control signal x 5 (RJ-45 8P modular jack) Power ON/OFF Switch CABLE COMP Y Control, CABLE COMP C Control x 4 (Coaxial Cable 3 pcs., 10BASE-T straight cable 1 pc.) (In case of using G/L function) pan/tilt head x 4 (Coaxial Cable: 3 pcs., 10BASE-T straight cable: 1 pc.)
  • Page 27: Accesories

    Operating temperature Dimensions Weight Finish Weight and dimensions indicated are approximate. Specifications are subject to change without notice. ACCESSORIES Rack mounting part ... 2 Mounting screws ... 4 10°C to +45°C (14°F to +113°F) 420 (W) x 88 (H) x 250 (D) mm [16-9/16" (W) x 3-7/16" (H) x9-13/16” (D)] kg (8.8 lbs.) Cover: AV Ivory vinyl chloride steel Panel: AV Ivory painting...
  • Page 28 Broadcast & Television Systems Company Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 2E-6, Secaucus, NJ 07094 Regional Offices: EASTERN ZONE: 43 Hartz Way, Secaucus, NJ 07094 (201) 348-7620 CENTRAL ZONE: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5200...

Table of Contents