The list of error codes is shown below.
Check the error code in the display panel and address the issue by referencing the information below.
Error code
E010
Abnormal in grid (High grid voltage)
Abnormal in grid (Low grid voltage)
E020
→ Especially when power fails.
E030
Abnormal in grid (AC over frequency)
E040
Abnormal in grid (AC under frequency)
E060
Abnormal in grid (Islanding)
E070
Abnormal in grid (Instant over voltage)
Abnormal in grid (Decrease in
E080
instantaneous voltage)
P170
Under voltage
P300
Overload
U030
Overload ("P300" 10 times in a row)
U060
Under voltage ("P170" 10 times in a row)
P620, P690
Battery module is over discharged.
P660, P700
Battery module is high temperature.
There is a problem with the storage battery
P350
system. Or internal DC protector is off. Or
the lines are disconnected.
P430, U020
Communications anomaly
H010-H490
There is a problem with the battery module.
There is a problem with the storage battery
H500-H990
system.
F010-F490
There is a problem with the battery module.
There is a problem with the storage battery
F500-F990
system.
The PXXX other
There is a problem with the storage battery
than those above
system.
The UXXX other
There is a problem with the storage battery
than those above
system.
H290
Battery lifespan
Description/where to check
The system operation will resume automatically as
soon as the commercial power supply is normal.
Please check the load which is connected to an
electrical outlet for backup. Its operation will resume
automatically after an abnormal eliminated.
After the battery is charged by a grid power, starts
the normal operation.
If the temperature of the built-in battery falls within
the operating temperature range, this product will
resume operation automatically.
Please contact the repair service.
Please contact the repair service.
Please contact the repair service.
After an abnormality is eliminated, this product will
resume operation automatically.
When operations do not resume, please contact the
repair service.
Please restart the operation.
Press the "ON/OFF (CANCEL)" for three seconds to
clear the error.
Please contact the repair service.