Chapter 7 Appendix — Attaching the Long Life Filter Unit (optional)

Attaching the Long Life Filter Unit (optional)

The optional Long Life Filter Unit (Model No.: ET-EMFU330) uses two of the same standard air filter unit attached
to the projector or the Replacement Filter Unit (Model No.: ET-EMF330) (accessory/optional accessory). The
interval to perform maintenance/replacement of filters is extended roughly two times by attaching the Long Life
Filter Unit instead of the standard air filter unit.
When purchasing the optional Long Life Filter Unit (Model No.: ET-EMFU330), consult your dealer.
Attention
f Make sure to turn off the power before removing the standard air filter unit attached to the projector and attaching the optional Long Life
Filter Unit. (x page 68)
f Make sure that the projector is stable, and perform the maintenance in a safe place even if the filter falls accidentally.
Note
f When the optional Long Life Filter Unit (Model No.: ET-EMFU330) is attached, the eyebolts cannot be attached on that side of the projector.

Removing the air filter unit

First, remove the standard air filter unit attached to the projector.
Air filter cover fixing screw
Air filter cover
Fig. 1
1)
Turn off the power of the projector.
f When switching off the projector, make sure to follow the procedures in "Switching off the projector"
(x page 68).
2)
Remove the air filter cover.
f Use a Phillips screwdriver to turn the air filter cover fixing screw counterclockwise until it turns freely (Fig.
1), and open the air filter cover for approximately 90°, and then pull out in the direction of the arrow. (Fig. 2)
f Loosen the air filter cover fixing screw while holding the air filter cover with your hand.
3)
Remove the drop-prevention string.
f Remove the hook at the tip of the drop-prevention string attached to the air filter cover. (Fig. 3)
4)
Pull out the air filter unit.
i) Pull out the air filter unit from the tabs on the projector body (c) while slightly pressing the grip on the air filter
unit (a) inward as described with the arrow. (Fig. 4)
ii) Pull out the air filter unit. (Fig. 5)
f When pulling out, confirm that the air filter unit comes off from the tabs on the projector body (d).
f After pulling out the air filter unit, remove large foreign objects and dust from the air filter unit compartment
and the air intake port of the projector body if there are any.
f When the air filter unit is removed, proceed to "Attaching the long life filter mount clasp" (x page 239)
next.
238 - ENGLISH
Grip on the air filter unit (a)
Fig. 2
Grip on the air filter unit (b)
Fig. 3
Tabs on the projector body (d)
Air filter unit compartment and
the projector's air intake port
Tabs on the projector
body (c)
Air filter unit
Fig. 4
Fig. 5